The jet must be stopped to set up this option. Select the appropriate conduit length for the print head
fitted by using the left or right arrow keys.

Head Height

6.2.4
The jet must be stopped to set up this option. Pressure varies by 5 units for every metre above and
below the printer. You may change the value between -9.5 and +9.5 metres, however, print heads are
currently a maximum of 6 metres in length, so the maximum value here should be 6.0. Simply specify, in
terms of half or whole meters, how far above or below the printer the print head is mounted. For
practical purposes, the measurement should be made from the space bar of the keyboard to the print
head nozzle assembly. If the print head is mounted below the printer, the value should be inputting the
following format - X.Xm. If the print head is mounted above the printer it is not necessary to place + in
front of the value. The value may be entered simply as - X.Xm.
NOTE: Care must be exercised with this option; poor printer performance will result if incorrectly set.
This will automatically change the pressure reference from which the Solvent Add values
calculated and shown on the MONITOR JET menu.

Meter Counter

6.2.5
After turning on the meter counter, you can use the meter counter function in the data editing module.

Changing System Set Up

6.3

Print Head Code

6.3.1
This can only be entered if the jet is stopped. It will also need re-entering if a PCB or software is replaced.
To be used when a new print head has been fitted to the printer and/or when a reset to default has
occurred. The 14 digits are encoded as follows:
Velocity of Drop Reference
H
V
Head Type
0=Micro
1=Midi
2=Macro

Ref. Modulation

6.3.2
Displays the current Reference Modulation. A new reference value may be added with a User
.
Level 2 password
Guangzhou EC-PACK Packaging Equipment Co., Ltd.
(VOD)
V
V
V
V
G
G
Charge DAC
Gian
Normally 1000
56
EC-JET 1000Pro Continuous Inkjet Printer
Pressure Reference
0 through 255
G
G
P
P
P
C
Check Digit Modulo 10
checksum to ensure
code is entered
correctly
EJ68