1.Press F2 to switch to the camera,and the press F3 to switch to the reference point No.1.
2.Move the XY axis to make the camera crosshairs aligned with the center of reference
Point 1,and press OK to save.
3.Then press F2 to swith to Nozzle 1,and then move the XY axis to make Nozzle 1 aligned
with the center of the reference Point 1.Press OK to save.
4.Then press F2 to switch to Nozzle 2,and then move the XY axis to make Nozzle 2 aligned
with the center of the reference Point 1. Press OK to save.At this point,saving the 1st
reference point is completed.
I
n order to accurately set the three reference points,the setting method of the other two
reference points and reference Point 1 is the same.
The more accurate the setting parameter is,the more precise is the coordinate camera
instructing and the coordinate actual nozzle reaching.Recommend that do a three-point
correction when replacing the nozzle,the mounting effect will be greatly improved!
At this point,the basic parameter settings have been completed.But need to pay attention:the
coordinates of the suction,suction height,mounting height,three-point correction are the
settings must be dong for normal operation of the machine.The other speed settings can keep
the default parameters.