PROBLEM
POSSIBLE CAUSE
Cannot start scanning.
• [SQL] is rotated too far clockwise.
• Incorrect receive mode (LSB, USB or CW) is se-
lected.
• Scan edges are set to the same frequencies.
• 2 or more memory channels have not been pro-
grammed.
• No channels have been programmed with the se-
lected receive mode (when using mode select
scan).
Cannot
recall
memory
• Wrong operating mode is selected.
channels.
WFM signal is distorted.
• Not tuned to the proper frequency.
TROUBLESHOOTING
SOLUTION
• Rotate [SQL] counterclockwise.
• Set receive mode to one of FM, WFM or AM.
• Set scan edges to different frequencies.
• Program 2 or more memory channels.
• Program at least 2 channels with the selected re-
ceive mode.
• Push [V/M] to select memory mode.
• Set the frequency 30–50 kHz less.
13
REF.
p. 11
p. 12
p. 57
pgs. 25,
26, 27
pgs. 25,
26, 27
p. 23
p. 20
76