17.12 Removal of Stator (SmartPump™) – Testing /
Inspection Purposes Only
Note: The stator is not available as a separate spare part, Use this procedure for inspecting
and testing the stator only.
(a) Lay machine down or against a wall.
leaning the machine against a wall, ensure
that the machine is stable, and take
necessary precautions not to damage the
wall or the machine.
(b) Disconnect earth by sliding connector apart.
(c) Remove the three screws holding the Stator
assembly to the Housing Pump.
(d) Lower the stator assembly.
(e) Unclip the wiring harness cover by releasing
the two tabs from the top side of the stator
shield and unplug the harness from the
stator.
(f) The stator can now be electrically tested. If
a fault is shown and the stator needs to be
visually inspected, the shield cap can be
removed.
Reassembly:
Refit in reverse manner.
Note: Alignment arrows are moulded into the
stator shield and the rotor housing to aid in the
refitting process.

17.13 Removal of Pump Housing

(a) If the bowl is full of water, drain or bail as
much of the water as possible from the
machine prior to continuing. To assist with
bailing the water, the inner bowl can be
removed.
(b) Follow procedures for removal of stator
(refer to Section 17.12).
(c) Remove the hose clamps from the Drain &
Recirculation Hoses. Carefully remove the
two hoses while holding a bowl or container
under the hose to catch the remaining water
trapped in the hoses and pump.
(d) Undo the two screws holding the pump to
the outer bowl.
removed from the bowl by pulling down on
the two port tubes.
The pump can now be