Fault Mode; Table 5-7 Additional Offline Mode Screens For Each Gt Inverter In A Multiple Unit System - Xantrex GT2.8-AU-QC-230 Owner's Manual

Xantrex grid tie solar inverter
Table of Contents

Advertisement

Monitoring the Inverter
Additional Offline
messages for
multiple unit
systems

Fault Mode

Fault Mode causes
5–8
Multiple unit systems in offline mode display all of the message screens shown in
Table 5-6, plus the additional screens shown in Table 5-7. These additional
screens are displayed following the Time Online screen.
These screens are only displayed when multiple GT Inverters are connected by
network cables. If you continue to tap the unit, then the LCD continues to cycle
through all of the available offline mode screens.
Table 5-7 Additional Offline Mode Screens for Each GT Inverter in a Multiple
Unit System
Tap
Display
5th
Unit 0W
Today 1.25kWh
6th
Unit Lifetime
150kWh
When a fault state is detected, the appropriate fault message appears on the front
panel display at the next screen refresh (i.e., within 2 seconds). The GT Inverter
fault message screens are shown in Table 5-8.
These message screens only appear when there is a fault, and then flash alternately
with the Inverter Offline default screen (Table 5-5) until the fault is corrected.
Table 5-8 Fault Message Screens
Display
DC Voltage Fault
145.5V
AC Voltage Fault
280V
AC Current Fault
Power being produced by this unit now.
Cumulative energy produced by this unit today.
Lifetime energy produced by this unit.
The actual DC voltage is over or under the allowable range.
Self-clearing, no action required.
The PV array should be configured such that DC voltage
falls within the input voltage maximum power point range
specified for your model in "Electrical Specifications" on
page A–2.*
The actual AC voltage is over or under the allowable range,
as specified in "Electrical Specifications" on page A–2.
This is a utility fault; it will clear itself when the AC voltage
comes within the specified range.†
The AC output current is over the allowable limit, which is
0.5 A less than the maximum output fault current. See
"Electrical Specifications" on page A–2. The message clears
after 15 seconds if the output current falls below the limit.
Description
Description
975-0466-01-01