9 Changing charging parameters

The settings of the charging parameters can be changed at any time. To do
this, proceed as follows:
ü The device is disconnected from the 230 V mains supply.
ü The device is not connected to a battery.
1. Connect the mains plug to a 230 V mains supply.
2. As soon as the 'Ready for operation' LED lights up blue (after approx. 5 s),
press the Stop button for 10 s until all LEDs are flashing.
ð The device is in configuration mode.
3. Set the desired charging parameters as described in Setting the Charging
Parameters [
ð The charging parameters are changed.

10 Installation

Battery Connection
To install the device in the vehicle, proceed as follows:
1. Disconnect the battery from the on-board power supply.
WARNING! Disconnect the negative cable first.
2. Secure the positive cable of the device as close as possible to the vehicle
battery with a suitable fuse.
3. Connect the positive cable of the device to the positive terminal of the bat-
tery.
4. Connect the negative cable of the device to the negative terminal of the
battery.
5. Connect the vehicle battery to the on-board power supply.
ð The device is installed.
LEAB Automotive GmbH