LEAB RBC 1280 User Manual page 23

Hide thumbs Also See for RBC 1280:
Table of Contents

Advertisement

LEAB Automotive GmbH
PP100 - Freely ventilated lead-acid
Fig. 10: Charging characteristic PP100
In the range [-30 °C ... -35 °C] and [+45 °C ... +50 °C] the current is reduced to 0.
NOTE! This charging characteristic contains a detection for weak batteries:
0.5 V per cell. Make sure that you do not charge batteries with a smaller num-
ber of cells. For example, do not charge a 12 V battery with a 24 V charging
characteristic.
Voltage per cell
2.4 V/2.25 V
LEAB Automotive GmbH
12 V system
14.4 V/13.5 V
Thorshammer 6
15 Appendix
24 V system
28.8 V/27 V
24866 Busdorf
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rbc 2440Rbc 2480010103698201010369910101078270

Table of Contents