MERCHANDISER ELECTRICAL DATA

Refer to the technical data sheets and
merchandiser serial plate for electrical
information .

FIELD WIRING

Field wiring must be sized for component
amperes stamped on the serial plate . Actual
ampere draw may be less than specified .
ALWAYS CHECK THE SERIAL PLATE FOR
COMPONENT AMPERES

ELECTRICAL CONNECTIONS

All wiring must be in compliance with NEC
and local codes .

ELECTRICAL OUTLET

Before the merchandiser is connected to any
wall circuit, use a voltmeter to check that the
outlet is at 100% of the rated voltage . The wall
circuit must be dedicated for the merchandiser .
Failure to do so voids the warranty . Do not
use an extension cord . Never plug in more
than one merchandiser per electrical circuit .
• Always use a dedicated circuit with the
amperage stated on the unit .
• Plug into an outlet designed for the plug .
• Do not overload the circuit
• Do not use long or thin extension cords .
Never use adapters .
• If in doubt, call an electrician .
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

ELECTRICAL / REFRIGERATION

NEMA 5-20P
Plug
Self-contained models have factory-installed
power cords attached at the electrical box . If
a power cord is damaged, it must be replaced
by personnel qualified for this task to prevent
hazardous situations . FNGSC4 and FNGSC6
have 1 power cord . FNGSC8A have 2 power
cords .
Case models with two power cords must be
plugged in at all times to operate the case.
Merchandiser must be grounded.
Do not remove the power sup
Risk of Electric Shock. If cord(s) or plug(s)
becomes damaged, replace only with
a cord and plug of the same type.

REFRIGERATION

Each self contained model will have two
self-contained units with one dual circuited
evaporator . The correct type of refrigerant
will be stamped on each merchandiser's serial
plate . The merchandiser refrigeration piping is
leak tested .
FNGSC-A Self Contained Merchandisers
2-1
ply cord
ground.