6.3.2 Refilling with eyelets
Ensure that there are eyelets available in the storage container at all times.
Only fill up with eyelets up to the bottom edge of the container axis.
Image 6.3.2 Filling port for eyelet
6.4 Use during operation
6.4.1 Switching on
6.4.2 Inserting eyelets
(optional).
16
Fold the protective hood [3/6.2.1] up.
Remove the knurled screw [2] and slide the cover plate [1] to the side.
Fill the storage containers [3] no further than the container axis. Always
use the specified eyelets.
Close the filling port using the cover plate [1] and lock the cover plate with
the knurled screw [2].
Fold the protective hood [3/6.2.1] down.
Set the toggle switch [7/6.2.1] to "ON".
The control lamp in the toggle switch lights up.
Push the documents to be eyeletted against the stops [1/6.2.1] [2/6.2.1].
Initiate the eyeletting process by pressing the pushbutton or the foot switch
A work cycle takes place automatically.
Automatic eyeletting machine 102-50
Operation
Hang OM