Microflite Ultra 2000 - Magnetek HPV 900 AC Vector Drive

7b.6.2 Drive Parameters

The following is a list of the parameters in the drive. Also included are an explanation of the
parameter and how it should be set. Refer to Section 6b.3.3 for the initial programming of the
drive.
Parameter
Units
Feet per
Contract Car Speed
Revolutions
Contract Mtr Speed
per Minute
Response
Radians
Inertia
Seconds
Radian per
Inner Loop XOver
Second
Percentage
Gain Reduce Mult
of Gain
Percentage
Gain Chng Level
of Rated
Tach Rate Gain
Spd Phase Margin
Degrees
Ramped Stop Time
Seconds
Contact Fault Time
Seconds
Brake Pick Time
Seconds
Brake Hold Time
Seconds
Percentage
Overspeed Level
of Rated
Overspeed Time
Seconds
Revision: AA 2.2
Adjust A0
Drive A1
Value
Contract Speed
Minute
Motor RPM at
Contract Speed
10.0
2.0
2.00
100
0.00
Speed
None
0.00
80.0
0.20
0.50
1.00
0.20
115
Speed
1.00
Printed 03- 15 - 03
Description
This parameter tells the drive what the rated speed of the car is. It is
used to display the speed of the car and the speed command in FPM
at the Elevator Data D1 menu.
This parameter tells the drive the RPM the motor should be turning
when the car is turning at rated speed.
This parameter controls the responsiveness of the speed regulator. It
sets the band width of the speed regulator. Larger numbers make the
system more responsive.
This parameter tells the drive the moment of inertia of the system.
See section 7b.5 for set up procedure.
This parameter controls the frequency of the inner speed loop
crossover in the speed regulator.
This parameter sets the amount of gain for the speed regulator to
use in the Gain Reduce mode. It is a percentage, and modifies the
Response parameter.
This parameter sets the speed at which the Gain Reduce mode
becomes active.
This parameter is controls the Tach Rate Gain function. It should not
be used except to tune out vibrations which cannot be removed by
any other means. Contact O. Thompson before activating.
This parameter sets the phase margin of the speed regulator,
assuming a pure inertial load.
This parameter sets the ramp down of the motor torque after the
drive is stopped.
This parameter sets the maximum amount of time the drive will wait
for the main contactor's auxiliary contact before declaring a
Contactor Fault.
If the Brake Pick fault is enabled, this parameter sets the maximum
amount of time the drive will wait for the brake's contactor's auxiliary
contact before declaring a Brake Pick Fault. Not activated on O.
Thompson controls.
If the Brake Hold fault is enabled, this parameter sets the maximum
amount of time the drive will wait for the brake's brake hold feedback
to match the brake pick command before declaring a Brake Hold
Fault. Not activated on O. Thompson controls.
This parameter sets the speed level at which an Overspeed fault is
declared. Set in conjunction with Overspeed Time.
The amount of time the overspeed condition must exist before an
Overspeed fault is declared. Set in conjunction with Overspeed
Level.