Outputs From The Dispatcher - O. Thompson Microflite Ultra 2000 Installation & Adjustment Manual

Table of Contents

Advertisement

CREC
nD or nDF
nDR
EC
EMG
EPn
FBY
FRST
HBF
HP
nIDF
nIDR
IRn
nIUF
nIUR
nLF nLK Nhl
LKO
nM or nMF
nMR
NPWR
OFFL
OFFR
PTS
REC
RECL
RECR
RET1
RET2
SASW
SEC
nU or nUF
nUR
12.4

Outputs from the Dispatcher

The following is a list of typical outputs for the dispatcher.
OP
UPP
DNP
nUC...nUC
nDC...nDC
nUX...nUX
nDX...nDX
nUA...nUA
nDA...nDA
nUY...nUY
nDX...nDX
DF
HF
RET1
RET2
LMAN
LAUT
Revision: AA 2.2
Microflite Ultra 2000
Third (C) smoke detector
Front down hall calls (F is shown only if there are any rear calls in the
system)
Rear down hall calls
Energy conservation
Emergency power input
Emergency power manual car select switch (followed by car number)
Fire bypass switch
Fire reset switch (ANSI/ASME 2000 Code only)
Hall button failure
High performance
Alternate riser front down hall call
Alternate riser rear down hall call
Inconspicuous riser car
Alternate riser front up hall call
Alternate riser rear up hall call
Front up and down hall call lock
Lock all non-lobby car calls on all cars
Front medical emergency hall calls
Rear medical emergency hall calls
Emergency Power - Return to Normal Power
Canadian hall fire recall switch lobby off
Canadian hall fire recall switch remote off
Pre-Transfer Switch on Emergency Power
Lobby fire recall switch
Canadian hall fire recall switch lobby on
Canadian hall fire recall switch remote on
Linked dispatcher has completed Emergency Power Phase 1
Linked dispatcher has completed Emergency Power Phase 2
Seismic activity switch
Security
Font up hall calls
Rear up hall calls
Off peak light
Up peak light
Down peak light
Up cross cancellation front outputs
Down cross cancellation front outputs
Up cross cancellation rear outputs
Down cross cancellation rear outputs
Up annunciator light front outputs
Down annunciator light front outputs
Up annunciator light rear outputs
Down annunciator light rear outputs
Dispatcher failure light
Hall button failure light
Linked dispatcher has completed Emergency Power Phase 1
Linked dispatcher has completed Emergency Power Phase 2
Canadian car Fire Phase I
Canadian car when smoke detector activates Fire Phase I
Printed 03 - 15 - 03