LW- to the car top encoder. Route the cable through the knockout in the K-Tech electronics
box to the Encoder. Confirm that K-Tech terminal LW+ is connected to Encoder terminal J3-1
and K-Tech terminal LW- is connected to encoder terminal J3-2. Ground the shield of the
cable inside the Encoder box.
Connect the terminal "Input 1" (J4) on the K-Tech electronics board to terminal "CAL" on the O.
Thompson Car Station board. Refer to the O. Thompson wiring diagrams for the exact terminal
location, as it will vary on job to job basis. This signal will be activated periodically by the Car
Station board, energizing the relay on the K-Tech board to re-calibrate the crosshead sensor.
The electronics box is now connected, the sensor mounted, and the unit is ready to be
calibrated.
9.3.5

Calibration

Apply power to the controller and allow it remain on for at least 30 minutes prior to adjusting
the unit. Failure to do this could require the unit to be re-adjusted later. If possible, perform the
calibration while standing off the car top. If this is not possible, be sure to stand in the same
position for each procedure.
Empty Car, Bottom Floor
1.
Bring the car to the lowest landing. There should be nothing in the car or on top of it.
Revision: AA 2.2
Microflite Ultra 2000
Printed 03 - 15 - 03
9 - 8