11.7.10 Event Disable Parameters Menu
This menu allows the user to disable certain events from registering in the event log. The controller
will still behave the same way if the event occur, but the event will not be noted in the event log.
This is helpful if there are certain events that occur frequently on a particular job that you do not
wish to log. To view what each event is use the cursor to move to the event number. The event
description will be shown at the bottom of the screen.
11.7.11 Car Call Lock Entry Menu
This menu allows you to lock out car calls for specific floors. These locks are not able to be
overridden by any hardware locks, but are overridden for Fire Service operation. This menu is
helpful if there is a particular floor in the building that is not in use and the customer wants that
floor locked out until a later time.
11.7.12 Up Hall Lock Entry (Simplex / IR only) Menu
This menu acts the same as the car call lock entry menu. It is only accessible on simplex cars or cars
with inconspicuous risers.
11.7.13 Down Hall Lock Entry (Simplex / IR only) Menu
This menu acts the same as the car call lock entry menu. It is only accessible on simplex cars or cars
with inconspicuous risers.
11.7.14 Floor Landing Value Menu
This menu is where the floor locations for the system are located. After a learn trip is completed the
menu item "PRESS ENTER TO GET FLOOR VALS FROM THE INCREMENTAL ENCODER" is
selected. This retrieves the values from the encoder that were observed on the learn trip. It may be
desirable to 'touch up' some of the floor values after the learn trip. To do this use the key pad on
the display card and manually change the value for a particular floor to that which will allow the car
to stop exactly floor level.
NOTE: It is recommended that the values only be changed by a maximum of 4 counts. If the value
needs to be changed more then it is necessary to remove the magnet and re-install it in the correct
position. After this is done another learn trip will need to be completed. FOR VALUES TO TAKE
EFFECT, RETURN TO MAIN MENU AND WRITE THEM TO NON-VOLATILE MEMORY.
Return to the main menu by pressing the '0' key when the cursor is on "RETURN TO MAIN
MENU". You can leave the parameter entry screen without saving your data at any time and return
to the main menu by pressing the reset button (S1 button on CPU card). Values entered are not
.
permanently stored in memory until the "W
V
N
-V
M
" option is selected
RITE
ALUES TO
ON
OLATILE
EMORY