Advertisement

Quick Links

oPeratinG anD installation
instrUCtions
insPire 40-40h / 45-45h / 55-55h stove
is exempt for use in smoke control areas when burning dry wood
eCoDesiGn reaDy
www.heta.dk
en
Danish DesiGn . Danish QUality . Danish ProDUCtion
1

Advertisement

Table of Contents
loading

Summary of Contents for Heta INSPIRE 40-40H

  • Page 1 40-40h / 45-45h / 55-55h stove is exempt for use in smoke control areas when burning dry wood eCoDesiGn reaDy www.heta.dk Danish DesiGn . Danish QUality . Danish ProDUCtion...
  • Page 2: Declaration Of Performance

    Signed on behalf the manufacturer of 18.08.2016 ____________________________________________________________________________________________________________________ In case of any change of the above-mentioned production type this Declaration of Performance becomes invalid. Heta A/S, Jupitervej 22, DK-7620 Lemvig, Tlf. +45 9663 0600, www.heta.dk Page 1 of 1...
  • Page 3 Signed on behalf the manufacturer of 19.09.2016 ____________________________________________________________________________________________________________________ In case of any change of the above-mentioned production type this Declaration of Performance becomes invalid. Heta A/S, Jupitervej 22, DK-7620 Lemvig, Tlf. +45 9663 0600, www.heta.dk Page 1 of 1...
  • Page 4 Signed on behalf the manufacturer of 18.08.2016 ____________________________________________________________________________________________________________________ In case of any change of the above-mentioned production type this Declaration of Performance becomes invalid. Heta A/S, Jupitervej 22, DK-7620 Lemvig, Tlf. +45 9663 0600, www.heta.dk Page 1 of 1...
  • Page 5: Table Of Contents

    Congratulations on your new wood stove, we are confident that you will be more than satisfied with your new Heta stove. Especially if you follow the following advice and instructions. Inspire 40-40H, 45-45H and 55-55H wood stoves are approved according to EN 13240, NS 3058 and 3059.
  • Page 6: Before Installation

    It is important that upon receipt check your Heta product completely and report any damage or defects to your dealer. The packaging must be disposed of as follows: Wood is untreated and able to burn in the stove.
  • Page 7 Ash pan handle Heta glove 1020-0001 Data plate 2 x M8x25 0008-0206 8150-0000-DK 2 x M6x30 0008-1118 DOP-Inspire 40 Indsats-2215-2016 Heta A/S Jupitervej 22 7620 Lemvig Denmark Produktions år: 2016 2 x Washer 0008-0501 DS/EN 13229/A2:2004/NS 3058/3059 Produkt beskrivelse Serie nr:...
  • Page 8: Operating Instructions

    1. oPeratinG instrUCtions 1.1 Before using Before the wood stove is used make sure required installation conditions, are met. See page 19. The use of lighter fluid, oils or any Baffle Plate liquid fuels is strictly forbidden from use in a wood stove. Fully open the combustion air into the start-up retainer air position and the door ajar (about one cm...
  • Page 9: Emptying The Ash

    rating air. When the fire is well established, you can now regulate the operating air to the desired combustion level. Rated output (see DOP of page 2) measured when the combustion air is about 80% open. Ensure when refueling that the wood is not too close, it will cause poorer combustion, less heat 1020-0001- out-put and lower efficiency.
  • Page 10: Draft Conditions In The Chimney

    Good draft occurs when: Minimum chimney draft for Inspire 40-40H: 13 pascal, Inspire 45-45H: 12 • The difference in temperature in the chimney pascal and Inspire 55-55H: 12 pascal. (warmer) and outside temperature (colder) It is the draft that the stove has been tested and •...
  • Page 11: Operating Problems

    release chimney. Similarly, you must not fire your stove with refuse, painted wood, pressure-impregna- At combustion 1000 litres of heating oil forms ted wood or chipboard, as these materials can 3.171 tons CO . As wood is a CO neutral heat/ emit poisonous fumes and smoke.
  • Page 12: Troubleshooting

    1.13 troubleshooting table Fault Cause Troubleshooting Solution Inadequate chimney draft. You can test using a lighter whether Improve the chimney. Lighting problems. When the The chimney only has stove is cold, smoke seeps flame is drawn into the combustion sufficient draft when it is hot. into the room.
  • Page 13: Maintenance

    1.14 Maintenance 1.15 Cleaning the glass Incorrect firing, for example using wet wood, The surface of the stove is treated with a heat- can result in the viewing window becoming resistant paint. The stove should be cleaned covered in soot. This soot can be easily and with a damp cloth.
  • Page 14: Cleaning/Replacing Bicks After Chimney Sweeping

    Note: it may be necessary to clean/vaccum the holes and air ducts behind the rear stone Order of removing Fire bricks. Inspire 55-55H Inspire 40-40H + 45-45H Replace in reverse order. Starting with Fig. 6.
  • Page 15: Parts Inspire 40-40H

    1.18 Parts inspire 40-40h stove - 5 x2 2 x4 13 - 14 - 15 - - 16 Pos. No. Name Qty. Pos. No. Name Qty. 1 5013-0008 Handle 0030-0201 Shaking grate, Ø195 mm 1 2 5013-0009 Set of glass clips...
  • Page 16: Parts Inspire 45-45H

    1.19 Parts inspire 45-45h stove - 5 x2 -2 x4 13 - - 10 15 - - 17 - 21 18 - 16 - - 11 19 - - 20 - Pos. No. Name Qty. Pos. No. Name Qty. 1 5013-0008 Handle 0030-0201 Shaking grate, Ø195 mm 1...
  • Page 17: Parts Inspire 55-55H

    1.20 Parts inspire 55-55h stove - 5 x2 -2 x4 13 - - 10 15 - 18 - - 17 - 21 16 - 19 - - 20 - - 11 Pos. No. Name Qty. Pos. No. Name Qty. 1 5013-0008 Handle 0030-0201 Shaking grate, Ø195 mm 1...
  • Page 18: Stove Data Table En 13240

    The nominal output is the output to which the stove has been tested. The test was carried out with the combustion air 65%. 1.21 Guarantee Heta wood stoves, subjected to a strict quality Should you have cause to make a complaint, control during production and before delivery to please quote our invoice no.
  • Page 19: Installation Instructions

    installation instructions Contents Installation instructions ..............20 Distance requirements ..............20 Floor ....................20 Chimney connection ................. 20 Combustion air and ventilation ............21 Stovedrawings/measurments ............22 Clearances for installation - EN 13240 40-45-55 ......23 Clearances for installation - EN 13240 40H-45H-55H .......24 Mounting the flue collar ..............
  • Page 20: Installation Instructions

    We recommend that you let a professional Heta dealer install the stove. Alter- In front of the fireplace insert, the substrate natively, you can ask the local chimney sweep must consist of non-combustible material, for before installation.
  • Page 21: Combustion Air And Ventilation

    / or 2010) especially when installing in newer build beading. Heta A/S stresses that it is of utmost properties when the stove is not going to be in- importance that this is done correctly with very stalled to an outside air supply.
  • Page 22: Stovedrawings/Measurments

    2.5 stovedrawings/measurments Type Inspire 40 Inspire 40H Inspire 45 Inspire 45H Inspire 55 Inspire 55H F: Measurements to openings...
  • Page 23: Clearances For Installation - En 13240 40-45-55

    2.6 Clearances for installation en 13 240 - inspire 40-45-55 Not combustible material Combustible material - Insulated flue Min. The dimensions are the minimum dimensions, unless otherwise stated. Snit A-A Snit B-B Clearances Stove Distance to flamable materials Minimum dimensions rear the at the door bottom...
  • Page 24: Clearances For Installation - En 13240 40H-45H-55H

    2.7 Clearances for installation en 13 240 - inspire 40h-45h-55h Not combustible material Combustible material - Insulated flue Min. The dimensions are the minimum dimensions, unless otherwise stated. Snit A-A Snit B-B Clearances Stove Distance to flamable materials Minimum rear the at the door bottom over...
  • Page 25: Mounting The Flue Collar

    2.8 Mounting of the flue collar 4025-0007- 2.9 Changing to a back outlet DETAIL D SCALE 1 : 1.5 4012-0004 - 4025-0007-...
  • Page 26 3. appendix a The Clean Air Act 1993 and Smoke Control Northern Ireland. Therefore it is a requirement Areas Under the Clean Air Act local authorities that fuels burnt or obtained for use in smoke may declare the whole or part of the district of control areas have been ”authorised”...

This manual is also suitable for:

Inspire 45-45hInspire 55-55h

Table of Contents