Clearances For Installation - Heta Vista Operating And Installation Instructions

Insert stove is exempt for use in smoke control areas when burning dry wood
Table of Contents

Advertisement

2.5 vista
Clearances for installation en 13 229
The Building materials that are used in safety test and shown in illustrations on this page, has a
thickness of 40 mm and a thermal conductivity of max. (=<0,066 W(m*K).
Seen from the front
1000
750
Seen from above
B
A
150
300
E
Distance combustible material
Minimum dimensions
Variant
A
B
Vista
110
150
18
Min. 365 mm
from
top edge of
convection outlet
to a combustible
material
Convection return
area over the insert
min. 722 cm
Min 895 mm from
lower edge of
convection return to
convection vent
Convection intake
area under the insert
min. 714 cm
Insulated with
min. 40 mm
Lambda value
(Thermal conductivity
= 0,066 W/mK)
Combustible
A
150
in mm
C
D
E
1100
300
284
Seen from the side
2
2
Seen from above
F
The dimensions are the
minimum dimensions,
unless otherwise stated.
F
480
Insulated chimney by
combustible
Uinsulated pipe
C
645
Distance to furniture