Hantek Tablet1000 Series Quick Manual

Tablet oscilloscope
Hide thumbs Also See for Tablet1000 Series:

Advertisement

Tablet1000
series
Tablet oscilloscope
Quick Guide
2022.05

Advertisement

Table of Contents
loading

Summary of Contents for Hantek Tablet1000 Series

  • Page 1 Tablet1000 series Tablet oscilloscope Quick Guide 2022.05...
  • Page 2 Hantek certified Tablet1000 series oscilloscope to meet China's national industry standards and has passed the CE certification. Contact us If you have any questions when using the products of Qingdao Hantek Electronics Co., LTD., you can obtain service and support through the following ways: Email: service@hantek.com, support@hantek.com...
  • Page 3: Safety Requirements

    Do not touch exposed connectors and components after power is switched on. ⚫ Do not operate if the product is suspected to be faulty. If you suspect that the product has been damaged, please ask qualified maintenance personnel to check it. Copyright © Qingdao Hantek Electronics Co., LTD Tablet1000 Quick guide...
  • Page 4 Safety terms on products: Warning: Indicates a potential hazard may be caused to you if you do not perform this operation. Safety signs on the product: Measurement category Measurement category Tablet1000 Quick guide Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 5: Working Conditions

    Operating and not operating: 3,000m (10,000 ft). Random vibration: 0.31g RMS at 50Hz to 500Hz, 10 minutes per axial direction. Not operating: 2.46g RMS from 5Hz to 500Hz, 10 minutes per axial direction. Copyright © Qingdao Hantek Electronics Co., LTD Tablet1000 Quick guide...
  • Page 6: Maintenance And Cleaning

    1) Using a lint-free cloth to remove the dust from the outside of the oscilloscope and Tablet1000 Quick guide Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 7: Environmental Precautions

    Copyright © Qingdao Hantek Electronics Co., LTD Tablet1000 Quick guide...
  • Page 8: Document Overview

    Acquire menu. Document content conventions: Tablet1000 series tablet oscilloscope consists of the following models. Unless otherwise specified, this manual uses TO1254D as an example to describe the Tablet1000 series and basic operations. Model Channel Bandwidth Sampling rate...
  • Page 9 1GSa/S TO1154C 150MHz 1GSa/S TO1204C 200MHz 1GSa/S TO1254C 250MHz 1GSa/S TO1154D 150MHz 1GSa/S 25MHz TO1204D 200MHz 1GSa/S 25MHz TO1254D 250MHz 1GSa/S 25MHz TO1154AUTO 150MHz 1GSa/S 25MHz TO1204AUTO 200MHz 1GSa/S 25MHz Copyright © Qingdao Hantek Electronics Co., LTD Tablet1000 Quick guide...
  • Page 10 Document overview Model Channel Bandwidth Sampling rate Signal source Multimeter TO1254AUTO 250MHz 1GSa/S 25MHz Table 2.1 Model21 Tablet1000 Quick guide Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 11: General Checking

    Check the machine If you find the instrument is damaged, not working properly, or unable to pass the performance test, please contact the dealer responsible for this business. Copyright © Qingdao Hantek Electronics Co., LTD Tablet1000 Quick guide...
  • Page 12: Product Introduction

    Powered by 4 or 2 18650 lithium batteries; With a supporting stand, able to use and place anywhere. Front panel Figure 4.1 Front panel41 1 Trademark Label 2 Touch button 3 LCD Tablet1000 Quick guide Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 13: Rear Panel

    Product introduction Rear panel Figure 4.2 Rear panel42 1 The supporting stand User interface Figure 4.3 User interface43 1 Oscilloscope 6 Pictures Copyright © Qingdao Hantek Electronics Co., LTD Tablet1000 Quick guide...
  • Page 14 Product introduction 2 Multimeter 7 Battery 3 Signal source 8 Power switch 4 File Browsing 9 USB icon 5 Settings 10 Hantek icon Tablet1000 Quick guide Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 15: Preparation Before Use

    Set the system language This oscilloscope supports Chinese and English. Click [HOME] to enter the main interface and click [Settings] > Language to select the language. Copyright © Qingdao Hantek Electronics Co., LTD Tablet1000 Quick guide...
  • Page 16: Functionality Check

    Connect one end of the probe to the CH1 channel and the other end to the AFG channel. Enter the oscilloscope interface, click Utility -> probe calibrate, and set the switch of the probe to 10X as prompted. Tablet1000 Quick guide Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 17 "compensated correctly" as shown above. If necessary, repeat Step 3. The adjustment method is shown in the following figure. Figure 5.3 Adjusting the probe53 Copyright © Qingdao Hantek Electronics Co., LTD Tablet1000 Quick guide...
  • Page 18: Touch Screen Gestures

    The functions that can be achieved by kneading are: ⚫ Knead vertically to adjust the vertical gear of the waveform. ⚫ Knead horizontally to adjust the horizontal gear of the waveform. Figure 6.2 Kneading gesture62 Tablet1000 Quick guide Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 19 Drag the waveform to change the displacement and offset of the waveform. ⚫ Drag the cursor to change the cursor position. ⚫ Drag the trigger to change the trigger position. Figure 6.3 dragging63 Copyright © Qingdao Hantek Electronics Co., LTD Tablet1000 Quick guide...
  • Page 20: Setting Parameters

    "Delete" key or "Clear" key on the virtual keyboard. To modify characters that has been entered, delete the characters and enter the characters again. Input validation After input, click on the "Enter" button. Tablet1000 Quick guide Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 21 Increase or decrease the number. Click to enter. Left and right arrows to determine the number, up and down arrows to increase or decrease the number. Long press the up and down arrows to change the number continuously. Copyright © Qingdao Hantek Electronics Co., LTD Tablet1000 Quick guide...
  • Page 22: Remote Control

    After the installation is complete, the running IO software can be found in the lower right corner of the screen. ⚫ Open IO - > Connection Expert - > Interaction IO, open the command window, and input commands with reference to the Programming Manual. Tablet1000 Quick guide Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 23 Figure 8.1 Command window81 2. Software The user can use the upper computer software to control the instrument remotely. It is recommended to use the software provided by Hantek. You can go to Hantek website http://www.hantek.com ) to download the software.
  • Page 24: More Product Information

    Information. You can obtain the model, serial number, software version, hardware version, and firmware version of the instrument. Check optional component information and installation For more information, please refer to the relevant manual (you can go to Hantek website http://www.hantek.com ) to download).
  • Page 25 Addr: #35 Building, No. 780 Baoyuan Road, High-tech Zone, Qingdao, Shandong, China 266114 Switchboard: 400-036-7077 Email: service@hantek.com Tel: (0086)532-55678770 & 55678772 & 55678773 Zip code: 266114 Website: www.hantek.com Qingdao Hantek Electronics Co., LTD...