Preparation And Installation Of The Anchor Set - Siemens VersiCharge 8EM1390 A0 Series Installation Instructions Manual

Mounting on column
Table of Contents

Advertisement

Preparing the assembly
1. Carefully open the packaging.
2. Provide a suitable surface base on which to lay the column.
3. Carefully remove the column from its packaging.
4. Check the column for damage. Complaints filed after installation will not be accepted.
5. Check the package content (Page 16)
Risk of electric shock due to exposed electrical connections and components
Before starting the installation work, check that the supply cable has been disconnected
from the mains and secured against restart.
If damage or tampering is visible (e.g. on the enclosure, socket), do not operate the Wallbox.
Mounting
Follow the step-by-step instructions for mounting Wallboxes on the column. The following
sections describe how to mount the column and a Wallbox:
Preparation and installation of the anchor set (Page 21)
Mounting on the base/mounting platform (Page 25)
Mounting the wall-mounting bracket (Page 27)
Connecting the supply cable (Page 29)
Cover and lock (Page 31)
NOTICE
If not all Wallboxes belonging to the corresponding column are mounted and electrically
connected, observe the following:
The remaining supply cable(s) must be protected against contact with a clamp approved for
this purpose. Do not switch on the corresponding RCBO.
VersiCharge Column Mounting
Hardware Installation Manual, 06/2022, A5E51460654-AB
DANGER
Mounting / Installing / Connecting

4.3 Preparation and installation of the anchor set