Filter Check Monitor

6.4
The Filter Check Monitor displays a reminder for required filter replacement or cleaning, by
flashing the FILT segment in the display. See instructions on your filter or heating/cooling unit
for recommendations for interval setting.
When the selected interval has been reached, and required cleaning or replacement has been
performed press the RETURN button in any normal mode to reset the timer and turn off the
warning.
Locking the Keypad
6.5
To prevent accidental or undesired adjustment of the thermostat, the Keypad Lock feature
disables the operation of the keypad except for the backlight key. In order to lock the keypad,
press and hold both the and
segment in the display will flash once per second, and then appear continuously in the
display. The keypad is now locked.
To unlock the keypad, press and hold the
second. The LOCK segment will disappear and the keypad will become unlocked.
Adaptive Recovery Mode (ARM™)
6.6
This thermostat is equipped with a special feature to maximize your energy savings by
utilizing the most effective source of heating or cooling to meet your program needs during
recovery from setback (or setup) temperatures. Our Adaptive Recovery Mode (ARM™) feature
is designed to automatically calculate when to turn your first stage of your multi-stage
heating or cooling system to meet your upcoming comfort setpoint temperature setting. While
in normal operating mode, this feature will start calculating the start time for your first stage
two hours prior to the upcoming comfort setpoint temperature. During this two hour time
period it will monitor performance and control your system staging requirements. The second
(auxiliary) stages of heating or cooling will be available during this 2-hour period if required to
meet extraordinary heating or cooling requirements.
Recirculating Fan Mode (see section 5.3.5)
6.7
The Recirculating Fan Mode provides more even temperature distribution and improves
indoor air quality by circulating air through the furnace filtration system more often. The
Recirculating Fan Mode can be selected by moving the fan switch to the recirculate position
(
). If no call for heating or cooling occurs within the fan off cycle set in section 5.3.5, the
fan will run for 12 minutes. The highest setting, 120 minutes (factory default), will run the fan
least often – 10% minimum run time. The lowest setting, 40 minutes, will run the fan most
often – 30% minimum run time. During any call for heating or cooling, fan control operates
in the AUTO mode. The Recirculating Fan feature is available in the HEAT, OFF, or COOL
mode.