Premier series 5-2 day programmable single stage heat/cool digital thermostat
Hide thumbs Also See for Premier 5000:

Advertisement

MODEL
5000
USER MANUAL
Compatible with low voltage single stage gas,
oil or electric heating or cooling systems,
including single stage heat pumps. This
thermostat can also be used on 250mv to
750mv millivolt heating only systems. Do not
use this thermostat on applications with
voltages above 30 Volts AC.
READ ALL INSTRUCTIONS BEFORE PROCEEDING
CONTENTS
1

SPECIFICATIONS

2

INSTALLATION

3
TESTING YOUR NEW THERMOSTAT
4
PROGRAMMING
5
ADDITIONAL OPERATION FEATURES
TROUBLESHOOTING
6
WIRING DIAGRAMS
7
© 2005 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 5000-100-005
Premier Series
5-2 Day Programmable
Single Stage Heat/Cool
Digital Thermostat
WARNING!
Important Safety Information
• Always turn off power to the air conditioning or heating system prior to installing,
removing, cleaning or servicing thermostat.
• Read this manual thoroughly prior to installing, programming or operating
this thermostat.
• This thermostat is designed for use with a 24 Volt-AC low voltage single stage
gas, oil or electric heating or cooling systems, including single stage heat
pumps. This thermostat can also be used on 250mv to 750mv millivolt heating
only systems.
• Do not use this thermostat on applications with voltages above 30 Volts AC.
• This thermostat requires two (2) properly installed "AA" alkaline batteries to
provide power for the thermostat to properly control the system operation.
• Wiring must conform to all building codes and ordinances as required by local
and national code authorities having jurisdiction.
• Do not short (or jumper) across terminals on the gas valve or at the heating or
cooling system control board to test the thermostat installation. This could
damage the thermostat and void the warranty.
• Do not select COOL mode of operation if the outside temperature is below
50˚ F (10˚ C). This could damage the controlled cooling system and cause
personal injury.
• This thermostat should only be used as described in this manual. Any other use
is not recommended and will void the warranty.
1
SPECIFICATIONS
• Electrical Rating: 24 Volt AC (18-30 Volt AC)
1 amp maximum load per terminal
2 amp total maximum load (all terminals)
• Control Range: 45˚ - 90˚ F (7˚ - 32˚ C)
• Accuracy: +/- 1˚ F (+/- .5˚ C)
• DC Power: 3.0 Volt DC (2 AA Alkaline batteries included)
• Compatibility: Compatible with low voltage single stage gas, oil or electric
heating or cooling systems, including single stage heat pumps. This thermostat
can also be used on 250mv to 750mv millivolt heating only systems.
• Terminations: Rc, Rh, G, W, Y, B, O
2
INSTALLATION
2.1
Replacing Existing Thermostat
1. Always turn off power to the air conditioning or heating system prior to removing
existing thermostat.
2. Remove the cover of your old thermostat and locate the wire terminals. Do not remove
wires from terminals yet.
3. Using small pieces of masking tape, label wires prior to removal from terminals. Use
the chart below to determine the new terminal designations for your new thermostat.
Old Terminal from
New Terminal for
Existing Thermostat
New Thermostat
V or Rc
Rc
M, 4, Rh, or R
Rh
G or F
G
H, W or 4
W
Y
Y
B
B
O
O
C
None-Cap the wire
Terminal Description
Cooling Transformer
Heating Transformer
Fan Control
Heating Control
Cooling Control
Reversing Valve (Heating)
Reversing Valve (Cooling)
24 Volt AC, Transformer Common
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Premier 5000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Braeburn Premier 5000

  • Page 1: Installation

    G or F Fan Control H, W or 4 Heating Control Cooling Control Reversing Valve (Heating) Reversing Valve (Cooling) None-Cap the wire 24 Volt AC, Transformer Common © 2005 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 5000-100-005...
  • Page 2: Testing New Thermostat

    INSTALLATION INSTALLATION cont. cont. Replacing Existing Thermostat Installing Your New Thermostat cont. cont. 19. Attach front body of thermostat to the sub-base, being careful to align the terminal 4. After labeling and removing all wires from terminals, unscrew the existing thermostat pins on the front body with the terminal block on the sub-base.
  • Page 3: Programming

    PROGRAMMING PROGRAMMING cont. Default Thermostat Settings Setting the Temperature Differential The default setting is 0.5˚ F (0.25˚ C). The room temperature must change 0.5˚ F (0.25˚ C) from Function Status After Reset the setpoint temperature before the thermostat will initiate the system in heating or cooling. Operation Mode Normal Operating Mode Temperature Hold...
  • Page 4: Programming Overview

    PROGRAMMING PROGRAMMING cont. cont. Entering Your Program Setting Recirculating Fan Cycle (see also section 5.7) 12. After pressing the RETURN button again, the 1. Place the system switch in the HEAT mode display will show "XXX OC SET” where XXX is of operation.
  • Page 5: Temporary Program Override

    ADDITIONAL ADDITIONAL OPERATION FEATURES OPERATION FEATURES cont. cont. Temporary Program Override Adaptive Recovery Mode (ARM™) 1. Press and hold button for 3 seconds. The In order to maximize comfort and energy efficiency, this thermostat is equipped with an entire display will flash once and the SET TEMP Adaptive Recovery Mode (ARM™).
  • Page 6: Troubleshooting

    ADDITIONAL TROUBLESHOOTING OPERATION FEATURES cont. Compressor Protection 5.10 SYMPTOM POTENTIAL SOLUTION This thermostat includes an automatic compressor protection feature to avoid potential Thermostat does not Check to see if OFF is shown in display. This indicates that the damage to the cooling system from short cycling. This thermostat automatically provides a system is turned off at the thermostat.
  • Page 7 TROUBLESHOOTING TROUBLESHOOTING cont. cont. SYMPTOM POTENTIAL SOLUTION SYMPTOM POTENTIAL SOLUTION This is above the normal thermostat temperature setting range Low battery indicator Replace batteries immediately to maintain proper system Thermostat will not of 45˚ to 90˚ F (7˚ to 32˚ C). operation.
  • Page 8: Wiring Diagrams

    2215 Cornell Avenue • Montgomery, IL 60538 NOTE: 1. For reversing valve active in heating, use B terminal instead of O terminal. Technical Assistance: www.braeburnonline.com Phone: 866-268-5599 © 2005 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 5000-100-005...

Table of Contents

Save PDF