Features; Specifications; Installation; Replacing Existing Thermostat - Braeburn Premier Series User Manual

Universal 7 day or 5-2 day programmable 2-heat/2-cool heat/cool digital thermostat
Hide thumbs Also See for Premier Series:
Table of Contents

Advertisement

1

FEATURES

• Contemporary Styling with large display
• 7 Day Programming Flexibility
• AC Powered with Battery Back-up (2 AA Alkaline batteries included)
• Preprogrammed for quick installation
• Meets Title 24 and Energy Star
• Extended "HOLD" Mode
• Compressor Short Cycle Protection
• Adjustable 1st & 2nd Stage Temperature Differentials
• Keypad Lockout
• Low battery Indication
• LED Status Indicator
• High Temperature Safety Switch
• Residual Cooling Fan Delay
• Recirculating Fan Mode
• Adaptive Recovery Mode (ARM™)
• Filter Check Monitor
• Maintains User Settings during Power Loss
2

SPECIFICATIONS

• Electrical Rating: 24 Volt AC (18-30 Volt AC)
1 amp maximum load per terminal
3 amp total maximum load (all terminals)
• Control Range: 45˚ - 90˚ F (7˚ - 32˚ C)
• Accuracy: +/- 1˚ F (+/- .5˚ C)
• AC Power: 18-30 Volt AC
• DC Back-Up Power: 3.0 Volt DC (2 AA Alkaline batteries included)
• Compatibility: Multi-stage heat / cool systems with up to two stages
of heating and two stages of cooling
• Terminations: R, Y1, Y2, W1, W2, G, O, B, C
3

INSTALLATION

3.1

Replacing Existing Thermostat

1. Always turn off power to the air conditioning or heating system prior to removing
existing thermostat.
2. Remove the cover of your old thermostat and locate the wire terminals. Do not remove
wires from terminals yet.
3. Using small pieces of masking tape, label wires prior to removal from terminals. Use
the chart below to determine the new terminal designations for your new thermostat.
Old Terminal from
Existing Thermostat
R, V-VR or VR-R
Y, Y1 or M
Y2
W1
W2 or W-U
G or F
O or R
B
C, X or B
4. After labeling and removing all wires from terminals, unscrew the existing thermostat
mounting base from wall. Make sure to secure wires to prevent them from slipping
back into the hole in the wall.
NOTE:
This thermostat is for use on low voltage 24 Volt AC multi-stage systems
with up to two stages of heating and two stages of cooling and requires a transformer
common wire for proper installation.
(Energy Saving Guidelines)
®
New Terminal for
New Thermostat
Terminal Description
R
24 VAC
Y1
1st Stage Cooling
Y2
2nd Stage Cooling
W1
1st Stage Heating
W2
2nd Stage Heating
G
Fan Control
O
Reversing Valve (Cooling)
B
Reversing Valve (Heating)
C
Transformer Common