On compressors equipped with an Elektronikon™ Swipe controller, the controller is provided with
potential free auxiliary NO contacts (NO = normally open) (K05, K07 and K08) for remote
indication of:
• Manual load/unload or automatic operation (K07)
• Warning condition (K08)
• Shut-down condition (K05)
Example: K05 is a NO (NO = normally open) contact. It will be closed if all conditions are normal
and will open in case of power failure or shutdown.
Maximum contact load: 10 A / 250 V AC.
Stop the compressor and switch off the voltage before connecting external equipment. Consult
your supplier.
Compressor control mode
On compressors equipped with an Elektronikon™ Swipe controller, consult the controller chapter
if it is desired to switch to another control mode.
On compressors equipped with an Elektronikon™ Touch controller, consult section
screen
if it is desired to switch to another control mode.
The following control modes can be selected:
• Local control: The compressor will react to commands entered by means of the buttons on
the control panel. Compressor start/stop commands via Clock function are active, if
programmed.
• Remote control: The compressor will react to commands from external switches.
Emergency stop remains active. Compressor start/stop commands via Clock function are
still possible.
Options:
• Remote starting and stopping (switch S1')
• Remote loading/unloading (switch S4')
• Remote pressure sensing (switch S' combined with pressure switch S4')
• LAN control: The compressor is controlled via a local network. Consult your supplier.
See service diagram 9828 5323 50 (9828 5323 51 for Ammann) to locate the connectors.
78
Have the modifications checked by your supplier.
Stop the compressor and switch off the voltage before connecting external equipment.
Only potential-free contacts are allowed.