The correct position for the electrical connection can be found on the dimension drawings.
Instructions
1. Provide an isolating switch.
2. Check that the motor cables and wires inside the electric cabinet are clamped tight to their
terminals.
3. Check the fuses and the setting of the overload relay. See section
fuses.
4. Connect earth conductor Earth terminal.
5. Connect the power supply cables to their terminals L1, L2, L3 and neutral if applicable.
Compressor status indication
On compressors equipped with an Elektronikon™ Touch controller, the controller is provided with
potential free auxiliary NO contacts (NO = normally open) (K05, K07 and K08) for remote
indication of:
2920 7118 31
Electrical connections
Designation
Customer's installation
All voltages (50 and 60 Hz)
Electric cable size and
77