Field installation
The main components are assembled ex-factory as a compact unit which fits inside the bodywork
of the compressor. Consult your supplier for installing and connecting the energy recovery unit.
82
Main components of the ER unit (typical installation)
Designation
Water inlet pipe
Water outlet pipe
Temperature sensor, water inlet pipe
Temperature sensor, water outlet pipe
Oil drain valve
Oil line from compressor oil separator vessel to ER unit
Oil line from ER unit to oil filter housing
Location of heat exchanger by-pass valve (BV2)
Heat exchanger
Selector valve
Oil separator vessel
Oil filter housing
Location of oil cooler bypass valve (BV1)