Programming

3.3 Initial Power-up

3.4 Programming Screens Description

See Page

3.5 Programming and Passwords

See Page
44
User Programming Levels
There are two user programming levels:
User Master Program Level 1 is used for programming panel specific data
relating to device types, zoning, messages, control panel functions, etc.
User Maintenance Program Level 2 is used by a qualified operator to access
features such as Disable/Enable, View and Clear History, Walktest and System
Time Change.
The following sections describe the initial programming procedures for a new system.
The same procedures are used to modify programming in an existing system.
After completing the wiring of addressable devices to the SLC, apply power to the
control panel. If the addressable devices have not yet been programmed into the FACP,
their LEDs will not flash and the following trouble message will be displayed.
TROUBL IN SYSTEM
NO DEVICES INSTALLED
09:03A 012102
Three options are available when the Enter key is pressed: Read Status, Programming
and Manual Dial Mode. The Read Status and Programming options have multiple
functions or features which may be chosen. To view all of the choices, it is necessary
that the programmer scroll through a number of additional subscreens. These
selections are displayed on multiple screens to make them more readable for the
programmer. Refer to "Master Programming Level" on page 46, for additional
information on the various screens.
The title of the main option screen will always be displayed at the top of the subscreens
for the programmer's convenience. If additional subscreens exist, an Up or Down
arrow will be displayed in the upper right corner of the screen being viewed. The
programmer can then press the keypad Up or Down arrow key to view the new
subscreen. To select one of the choices in a screen, the programmer presses the keypad
numerical key corresponding to the desired choice.
Note that subscreens may also have multiple options which require viewing more than
one screen. The same process, as detailed in the previous paragraphs, is followed to
view all option choices.
There are two factory set programming passwords which will access the Programming
screens as indicated in the following examples. From either of the screens, access to
specific system and device features or programming may be obtained. All user
programming entries are stored in nonvolatile memory. The factory set passwords can
be changed by the user as described in "Password Change" on page 116. If an invalid
password is entered, the blinking cursor will return to the first password character
position. To exit Programming, Read Status or Manual Dial mode at any time, press
the ESC (Escape) key repeatedly. Note that Programming mode must be exited using
the ESC key in order to store the program data entered during this mode. If the Reset
key is pressed or power is lost before exiting Programming mode, the data just entered
will not be saved.
Initial Power-up