When Check Character is set to Validate, but Don't Transmit, the unit only reads Matrix 2 of 5 bar codes printed with a
check character, but will not transmit the check character with the scanned data.
When Check Character is set to Validate and Transmit, the scanner only reads Matrix 2 of 5 bar codes printed with a
check character, and will transmit this character at the end of the scanned data. Default = No Check Character.
* No Check Character
Validate and Transmit
Matrix 2 of 5 Redundancy
If you are encountering errors when reading Matrix 2 of 5 bar codes, you may want to adjust the redundancy count. Redun-
dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.
Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan
the Matrix 2 of 5 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the
Chart
inside the back cover of this manual. Then scan the
Matrix 2 of 5 Message Length
Scan the bar codes below to change the message length. Refer to
information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80.
Minimum Message Length
6 - 10
Save
bar code. Default = 0.
Matrix 2 of 5 Redundancy
Message Length Description
Validate, but Don't Transmit
Programming
(page 6-1) for additional
Maximum Message Length