Ei25 LED Electric Fire Range with Thermostatic Remote Control Instructions for Use, Installation & Servicing For use in AU & NZ (Australia & New Zealand) IMPORTANT PARTS OF THE OUTER CASING OF THIS APPLIANCE ARE CONSIDERED BY THE MANUFACTURER TO BE A WORKING SURFACE WHICH BECOMES HOT WHEN THE HEATER IS IN OPERATION AND WILL RESULT IN SERIOUS INJURY AND BURNS IF TOUCHED.
CONTENTS Ei25 - LED Electric Fire Range Covering the following models: Ei25 210-430 User Instructions ............3 WARRANTY This system carries a 2 years parts-labour warranty. Installation Instructions ..........9 Please note that all warranties are effective from the date of purchase.
USER INSTRUCTIONS This appliance can be used by children aged from 8 years and IMPORTANT INFORMATION AND above and persons with reduced physical, sensory or mental HEALTH AND SAFETY capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
OPERATING INSTRUCTIONS WARNING! Do not operate the appliance if it is REMOTE CONTROL damaged or has malfunctioned. If you suspect the appliance is damaged or has malfunctioned call a suitably quality person to inspect the appliance, The remote control should be left on a flat surface in the room and replace any part of the electrical system if where the appliance is installed and away from any direct flow necessary, before reuse.
Page 5
FUEL BED COLOUR ADJUSTMENT OPERATING THE APPLIANCE - ADVANCED OPERATION Press to enter the fuel bed light adjustment screen. There are 15 fuel bed colour options, including off. Temperature Sensor Convection There are 5 levels of brightness. Display Power Flame Fuel Bed Heating Timer...
Page 6
Ensure that the handset batteries are new and inserted correctly. OPERATING THE APPLIANCE - TROUBLESHOOTING Dispose of old batteries at an appropriate recycling facility. Battery replacement is recommended after 1 year. BATTERY The Remote requires two 1.5V alkaline AAA batteries. The battery power level is indicated at the top right of the remote Ensure the correct polarity.
MAINTENANCE ENSURE THE APPLIANCE IS TURNED OFF BEFORE CLEANING. GLASS CLEANING Wipe the glass viewing panel with a damp cloth and buff with a lint free duster. Caution: Do not use abrasive cleaners on the glass panel. Do not spray liquids directly onto any surface of the unit. CLEANING THE FUEL EFFECT Remove and wash the fuel effect to remove any dust particles.
Page 8
CLEANING AIR INLETS Clean the air inlet and outlet grilles regularly with a soft cloth or the nozzle of a vacuum cleaner. Dust build-up can inhibit efficient performance of the fan and lead to the safety cut-out operating. Keep the area around the appliance clean and free of fluff, dust or pet hair.
TEST THE APPLIANCE BEFORE INSTALLATION. FITTING THE APPLIANCE LOCATING THE Ei25 Your new Ei25 may be installed virtually anywhere in your home. However, when choosing a location ensure that the general instructions are followed. For best results, install out of direct sunlight.
SERVICING REQUIREMENTS DURING SERVICING OF THIS APPLIANCE IT MAY BE NECESSARY TO CUT CABLE TIES IN ORDER TO ACCESS AND REMOVE SOME OF THE PARTS. THESE MUST BE REPLACED WHEN REASSEMBLING THE APPLIANCE. THIS APPLIANCE MUST ONLY BE SERVICED BY A SUITABLY QUALIFIED PERSON.
INSTALLATION 653mm 450mm 320mm Ei25 CONTROL SYSTEM TECHNICAL DATA MAIN CONTROL BOARD REMOTE RECEIVER BOARD REMOTE CONTROL Hardware RC01-086A V0 RF290I V1.2 RC290F V1.1 Software RC01-086A01 V0 RCS19-V01.06 Frequency FSK 433.92MHz Maximum Transmit Power 10mW Maximum power consumption: A 230-240VAC 10 Amp 50Hz supply is required...
LEVELLING LEGS NOTE: The levelling of the appliance must be done prior to sliding appliance into final position. The leveling bolts which are supplied must be installed with bolts from below as shown. Rest appliance on its back and secure 4 bolts as shown above.
LOG SET - LOG LAYOUT Glass Embers Amber Crystals Ei25...
Page 18
Place glass embers (H) evenly with white sides facing up. Apply tape to logs at white dot positions Adhesive Tape E x3 Adhesive Tape x1 F x2...
SERVICING PAIRING THE REMOTE ACCESSING THE FUEL BED SIGNAL CODE The below operations should be carried out before coding when changing to a new remote or the unit cannot be controlled by the remote: The reset button is located on the control panel located on the right-hand side of the appliance.
Page 21
REMOVAL OF THE FUEL BED Remove 4 rubber plugs using a small flat head screwdriver on grate (not shown) and then remove 4 screws ( 2 at back/2 at front) as shown below. x 13...
INFORMATION REQUIREMENT FOR ELECTRIC LOCAL SPACE HEATERS Model Ei25 Nominal Heat Output P nom 2.0kW Minimum Heat Output P min 1.0kW Maximum Continuous Heat Output P max, c 2.0kW At Nominal Heat Output el max 10.0W At Minimum Heat Output el min 9.5W...
WARRANTY LIMITED WARRANTY This product comes with an extended Limited Warranty to the original purchaser of this appliance provided the product remains in the original place of installation. Some conditions apply (see below). The policy is not transferable, amendable or negotiable under any circumstances. After the original warranty coverage has expired, any repair and/or replacement parts purchased by the consumer through an accredited distributor or dealer will carry a ninety (90) day warranty (valid only with an original copy of the tax invoice).
Page 36
WARRANTY EXCLUSIONS This Limited Warranty does not extend to paint, rust or corrosion of any kind due to a lack of maintenance or improper venting, combustion air provision, corrosive chemicals (i.e. chlorine, salt, air, etc.), firebrick (rear, sides or bottom), door or glass gasket, or any other additional factory fitted gasket.
WARRANTY LIMITATIONS OF LIABILITY 1. Exclusion of implied terms The customer may have the benefit of consumer guarantees under the Consumer Law. To the maximum extent permitted by law, all terms, conditions or warranties that would be implied into this Warranty or in connection with the supply of any goods or services by the supplier under law or statute or custom or international conventions are excluded.
Page 40
Fireplace Products Australia Pty Ltd 99 Colemans Road Dandenong South VIC, 3175 AUSTRALIA +613 9799 7277 www.regency-fire.com.au *PRPR3295AZ* PR3295AZ...
Need help?
Do you have a question about the Ei25 and is the answer not in the manual?