4000 Series Vandal Resistant Range
Art. 4212
Audio/video digital front panel

SYSTEM SETTINGS

System par. menu Parameter Name
1: Language
2: ID
3: Master

4: Panel mode

LANGUAGE
Languages supported are: English, Italian, Spanish, Portuguese,
French, German, Czech, Croatian, Danish, Polish, Slovenian,
Dutch and Hebrew.
Only user messages change language, the programming menu's
are always in English.
Modify routine
• press "1" to enter into edit mode;
• press "1" repeatedly to scroll through the available languag-
es;
• press
to save or
to exit edit mode without saving.
ID
The panel ID came be from 1 to 15. Each panel on a system
should have a unique ID.
Modify routine
• press "2" to enter into edit mode;
• Enter the panel ID from 1 to 15;
• press
to save or
without saving.
MASTER
Specifies if the panel is a master or a slave. On each bus there should
only be one master, all other panels on that bus should be slaves.
Modify routine
• press "3" to enter into edit mode;
• press "3" to enable or disable;
• press
to save or
to exit edit mode without saving.
PANEL MODE
Specifies if the system includes the Art.  2206N bus exchange
devices or not and if the panel is a main panel or a local panel. If
there are no Art. 2206N devices on the system then this setting
should be LOCAL. If there are Art. 2206N devices on the system
and this panel is a main entrance calling all apartments then this
setting should be MAIN. If the panel is a block entrance panel
then this setting should be LOCAL.
Modify routine
• press "4" to enter into edit mode;
• press "4" to switch from LOCAL to MAIN and viceversa;
• press
to save or
to exit edit mode without saving.
Art. 4212 - Installation instructions
Language
ID
Master
Panel mode
Security Level
Mode
Enable Direct Call
Proximity Access Mode Only by PC software
to delete characters or exit edit mode
Programming method
By panel and PC software
By panel and PC software
By panel and PC software
By panel and PC software
Only by PC software
Only by PC software
Only by PC software
SECURITY LEVEL
Art. 4212 can work in two different security modes: Fob or Code
and Fob + Code.
In Fob or Code, key and code are linked only with user. Insertion of
enabled code or passing a key over the reader will open the door.
In Fob + Code, key and code are linked together. Single code is
linked with single key.A user must enter a code and present a
key to open the door. Parameter can be changed only through
PC programming routine.
MODE
Options are COMPATIBILY MODE or NORMAL MODE.
COMPATIBILITY MODE guarantees retrocompatibility with older
programming interfaces but restricts the features of the panel.
NORMAL MODE enables features of floor field in user item,
multiple code-to-user or key-to-user linking. This means that
user can manage more than one open door code and key.
In COMPATIBILITY MODE each user only has one access code.
ENABLE DIRECT CALL
It specifies whether Direct Call Mode is active or not. If yes, only
the first 18 or 15 (depending on keyboard configuration) users
written in memory are active. Pushing the first key from top left
corner of keyboard will call first user memory location.
PROXIMITY ACCESS MODE
This parameter specifies if the proximity reader works in a self
contained standalone mode or is connected via a Wiegand in-
terface to an external controller such as Portal Plus.
STANDALONE MODE: when a fob/code is used the panels in-
ternal memory is checked for a match. If a match is found the
relay will energise and the display will show the door opening. If
no match is found the display will show 'NOT FOUND' .
WIEGAND MODE: When a fob/code is used the panel sends the
data to the Wiegand output and awaits a reply. If the external
Wiegand controller replies by setting the LR terminal to 0V then
the fob/code is denied and the display will show 'NOT FOUND' .
If the external Wiegand controller replies by setting the LG ter-
minal to 0V then the key is accepted and the display will show
door open. If the Wiegand control does not reply then the panel
will show 'NOT FOUND' .
- 11 -
Programming
Permission
Default value
Only Engineer
English
Only Engineer
1
Only Engineer
Enabled
Only Engineer
Local
/
Fob or Code
/
Compatibility mode
/
Disabled
/
Stand alone mode
66250203 - V4.4 - 15/05/22