CH6
0-5
6-127
128-255
CH7
0-255
Specifications:
Power supply
Fuse
Heating element
Reheat time
Fog output (approx.)
Tank capacity
LED power
RF Remote frequency
DMX connection
Dimensions
Weight
Troubleshooting
Warning: Hot components! ... Switch off and allow to cool before touching the unit.
No light on mains
switch
Ready message is
on but no fog
output
No response to
DMX
No LED output
This product is classed as Electrical or Electronic equipment and should not be disposed with other household or commercial waste at the end of its
Errors and omissions excepted.
Copyright© 2022 AVSL Group Ltd, Unit 2 Bridgewater Park,
Taylor Road, Trafford Park, Manchester. M41 7JQ.
www.avsl.com
No LED effect
LED color changing mode
LED gradual change mode
LED effect speed slow to fast
230Vac, 50Hz (IEC)
F10A
2000W
5 to 6 mins (approx.)
72,000 Cu Ft (1133m³)/ min
5.5 litres
3W x 6pcs
433MHz
XLR (3-pin/5pin) in/out (6-channel)
550 x 280 x 280mm
10kg
Check mains voltage is correct and socket is switched on
Check IEC lead is OK and connected properly
Check mains fuse in IEC connector and fuse in plug top
If fuse blowing repeatedly, refer to qualified service personnel
Check fog fluid level
If fluid is OK and pump working, the lines may be blocked
Check that nozzle is not blocked or obstructed
If blocked, clean with fog machine cleaner & distilled water
Check that XLR leads are connected properly
Check that DMX signal is OK by testing on other equipment
Check the DMX settings are set to the correct address
Ensure that the other remote control is not overriding DMX
Check LED settings on rear control panel
Check LED is not switched off on RF remote
useful life. The goods must be disposed of according to your local council guidelines.
AVSL (Europe) Ltd, Unit 3D North Point House,
North Point Bus. Park, New Mallow Road, Cork, Ireland.
160.478UK User Manual
Need help?
Do you have a question about the QTFX-2000LED and is the answer not in the manual?
Questions and answers