Table 2 Inverter Mode Specifications
MODEL
Rated Output Power
Output Voltage Waveform
Output Voltage Regulation
Output Frequency
Peak Efficiency
Overload Protection
Surge Capacity
Nominal DC Input Voltage
Cold Start Voltage
Low DC Warning Voltage
@ load < 20%
@ 20% ≤ load < 50%
@ load ≥ 50%
Low DC Warning Return Voltage
@ load < 20%
@ 20% ≤ load < 50%
@ load ≥ 50%
Low DC Cut-off Voltage
@ load < 20%
@ 20% ≤ load < 50%
@ load ≥ 50%
High DC Recovery Voltage
High DC Cut-off Voltage
DC Voltage Accuracy
THDV
DC Offset
100ms@≥205% load;5s@≥150% load; 10s@110%~150% load
2* rated power for 5 seconds
24Vdc
23.0Vdc
23.0Vdc
21.4Vdc
20.2Vdc
24.0Vdc
22.4Vdc
21.2Vdc
22.0Vdc
20.4Vdc
19.2Vdc
32Vdc
33Vdc
+/-0.3V@ no load
<5% for linear load,<10% for non-linear load @ nominal voltage
43
LV 6548
6500W
Pure Sine Wave
120Vac± 5%
60Hz or 50Hz
91%
48Vdc
46.0Vdc
46.0Vdc
42.8Vdc
40.4Vdc
48.0Vdc
44.8Vdc
42.4Vdc
44.0Vdc
40.8Vdc
38.4Vdc
64Vdc
66Vdc
≦100mV