6.5.1

Scaling Minimum / Maximum Values

When Input Mapping is used the user may specify the input signal range through the Input Minimum and
Input Maximum parameters. There is one pair of registers for each of the 4 possible outputs.
Sensor
0
1
2
3
When either the Low Scale or High Scale value changes an internal calculation is performed to calculate the
linear transformation to be applied to the sensor reading.
6.5.2

Output Values

Outputs use float values which represent the percentage of full scale. If the output is not mapped, the value
written (0 – 100%) is identical to the value that is read back.
If the output is mapped, the scaling values are used to transform the minimum input value to 0% and the
maximum input value to 100%.
Output
0
Output 0 Value
1
Output 1 Value
2
Output 2 Value
3
Output 3 Value
6.5.3

Output Names

Each output has a name. The default names for the outputs are Output_0 through Output_3. The default
names may be overwritten, such as 'Stack_Lite' or 'Control_Valve'. Names are restricted to 16 characters.
Output
0
Output 0 Name
1
Output 1 Name
2
Output 2 Name
3
Output 3 Name
The Output names are retained until a factory reset occurs.
It is strongly recommended that:
1. Spaces within the name should be replaced with the '_' character.
2. All output names on a particular device are unique – if duplicate functions are supported append a '_x'
string, where x represents the instance. For example, Stack_Lite_1 and Stack_Lite_2 could be used if 2
stack lights are being connected.
Name
Output 0 Low Scale
Output 0 High Scale
Output 1 Low Scale
Output 1 High Scale
Output 2 Low Scale
Output 2 High Scale
Output 3 Low Scale
Output 3 High Scale
Modbus
Name
Address
0xf078
0xf07a
0xf07c
0xf07e
Modbus
Name
Address
0xf078
0xf07a
0xf07c
0xf07e
Modbus
I2C
Address
Address
0xf1f0
0x03e0
0xf1f2
0x03e4
0xf1f4
0x03e8
0xf1f6
0x03ec
0xf1f8
0x03f0
0xf1fa
0x03f4
0xf1fc
0x03f8
0xf1f2e
0x03fc
I2C
Size
Address
0x00f0
float
0x00f4
float
0x00f8
float
0x00fc
float
I2C
Size
Address
char[16] Defaults to Output_0
0xf720
0xf728
char[16] Defaults to Output_1
char[16] Defaults to Output_2
0xf730
0xf738
char[16] Defaults to Output_3
Size
Description
float
Sets lower input range
float
Sets upper input range
float
Sets lower input range
float
Sets upper input range
float
Sets lower input range
float
Sets upper input range
float
Sets lower input range
float
Sets upper input range
Description
Percent of full-scale value (0-100%)
Percent of full-scale value (0-100%)
Percent of full-scale value (0-100%)
Percent of full-scale value (0-100%)
Description