Maximum Operating Pressure; Information About The Eu Pressure Equipment Directive 97/23/Ec; Flow Rate Measuring Range - Omega FHG Series User Manual

Flow meters
Table of Contents

Advertisement

3. Electronic Evaluation and Electrical Safety
Does the supply voltage of the flow meter match the available power supply?
Is the supply voltage to the power supply adapter or the evaluating device sufficiently filtered?
Does the output of the supply voltage correspond with the required output?
Is the electrical connection established based on the enclosed wiring plan (see page 19)?
Is the cable shield correctly grounded on both sides to a clean common ground (PE)?
Is there a potential difference between the ground on the flow meter and at the evaluating device?
Is the flow meter permanently grounded (PE) (e.g. via the pipelines)?
If the measuring element of the flow meter is insulated from ground (PE), the meter must be grounded with a cable!!
Is the 4-pin to 5-pin round pin plug of the connection cable firmly attached to the plug of the flow meter?
Are the wires at the evaluating device connected correctly?
Does the entire system meet the legal rules and regulations concerning electromagnetic compatibility (EMC)?
Is compliance with all local rule and regulations, applicable rules, guidelines and basic conditions of the EMC ensured?
Systems where a malfunction or failure may lead to personal injuries must be equipped with suitable safety mechanisms. The function of these
safety mechanisms must be checked at regular intervals.

6. Maximum Operating Pressure

Before installing the flow meter, you must check whether the max. operating
pressure of the system does not exceed the max. permissible operating
Important:
Please contact Omega with all operating pressures > 450 bar and in case of special models.

7. Information about the EU Pressure Equipment Directive 97/23/EC

Omega flow meters of the "FHG" series qualify as "pressure equipment" as
defined by Section 1, Paragraph 2.1.4. of the directive listed above and as
such are affected by the regulations of this directive.
Omega flow meters must therefore meet the technical requirements speci-
fied in Section 3, Paragraph 1.4 of the directive. The fluids to be measured
are for the most part Group 2 fluids acc. to Section 9, Paragraph 2.2.
Omega flow meters do not reach the limit values specified by Section 3,
Paragraph 1.1. The technical requirements for Omega flow meters are

8. Flow Rate Measuring Range

The flow rate measuring range specified in the data sheet (Q
of the flow meter refers to the test fluid ‚hydraulic oil' with a viscosity of
21 mm
2
/s at a temperature of 20°C. For this measuring range, Omega
specifies accuracy up to 0.3% of the measured value and a repeatability
of 0.05%.
Important:
Verify that the specified maximum permissible operating pressure of the flow meter
can never be exceeded in any operating mode of the system. Also pay attention to the
flow measuring range, which is dependent on the viscosity of the fluid to be measured.
pressure of 450 bar of the flow meter. Make sure to keep in mind that peak
pressures may occur when operating the system.
therefore confined to the criteria specified in Section 3, Paragraph 3. This
means that the devices must be designed and manufactured in accordance
with the provisions of good engineering practice applicable in a member
state. This is hereby confirmed. The section also stipulates that such pres-
sure equipment and components or accessories are not allowed to bear
the CE marking in accordance with the Pressure Equipment Directive. This
means that a declaration of conformity is not issued for Omega flow meters
and the devices are not provided with the CE mark as pertaining to Direc-
tive 97/23/EC.
– Q
)
In fluids with low viscosity (< 21 mm²/s), the measurement accuracy de-
min
max
grades while it may improve with fluid with a high viscosity (> 21 mm²/s).
Note also that the flow measuring range is limited at higher viscosity (see
data sheet of the flow meter). The characteristic pressure loss curves are
listed in Section 23.
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fhg 100Fhg 400Fhg 800Fhg 2500

Table of Contents