Assessment And Replacement Of Electric Element Ak1850 - Whale Heat Air SL5511Ux How-To Manual

Table of Contents

Advertisement

tel.: +44 (0)2891 270 531

4.10 Assessment and replacement of Electric Element AK1850

The failure of the electric element will be noted by the lack of room heating power when operating
the Heater in the electric mode. This can indicate that the electric element is either not connected
correctly or faulty and no longer operates, PCB is faulty or no mains supply to the Heater.
To assess which of the faults occurred and to take the correct action, replacement if required, please
follow the steps outlined below.
! Ensure 230V supply is isolated before commencing work on the product.
done with mains voltage present.
1
2
Ensure 12 V DC
Ensure Heater's
power supply is
230V AC cable
switched on
is connected to
supply
To remove and replace Room Heater casing refer to chapter 4.7.4
It is critical that the elements are correctly wired in their pairs alongside the overheat stat.
apply as illustrated below to ensure the connections from the elements to the PCB are not altered.
- ensure O/H Stat & electric element pairs
1
are marked as shown.
Element Pair 1
Element Pair 2
- replace the electric element by
4
hooking spring clips to heat exchanger
and clamping securely into the grooves
(see pic 3). Again, a flat-head
screwdriver will need to be used to
carry this out.
This data is confidential to Brunswick
Munster Simms Engineering Ltd., 2 Enterprise Road, Bangor, Co Down, BT19 7TA, U.K. – Northern Ireland
fax.: +44 (0)2891 466 421
3
Use current clamp to
check current draw.
Ensure mains cable is
connected and 230V
are present
- use long nose pliers to
2
remove the cables.
Overheat Stat
- using existing or new colour code, push cables onto the
5
connections, ensuring the wires are correctly installed in their
respective pairs and locations.
- ensure the wiring from the furthest end passes under other
connections when routing towards the PCB (check pic 2) and
do not become snagged when refitting the cover.
Heat Air Room Heater
info@whalepumps.com
Only measuring the current draw should be
- compare measured value with relevant reference
value in table above
- should the measured value be inconsistent with the
reference value, the element is faulty and requires
replacement
If no colour code exists,
- remove the spring clips by
3
prising them off with a flat-
head screwdriver.
Page
www.whalepumps.com
|
25 of 34