4.1.2 Clear lockout procedure iVan Control Panel

iVan is equipped with an electronic diagnostic system which will detect fault conditions ranging from
poor gas or d.c. supply to internal Heat Air Room Heater malfunctions. In the unlikely event of a fault,
this will be indicated by a red '!' on the Room Heater icon on the Home Screen.
Figure 6b – Room Heater fault indicator
The Room Heater will not operate when a fault is indicated on the home screen. A pop-up screen will
appear when you attempt to operate the Room Heater. The pop-up screen identifies the fault. As soon
as you have completed the suggested actions on the fault screens below, you must clear the fault
code by following the instructions on screen, where applicable pressing the RED Reset Button on the
Expanse Water Heater for 1 second (see Figure 6c) and pressing OK.
NB. Attempt to resolve the indicated issue before clearing the lockout.
Figure 6c – Reset Buttons on Water Heater Interface
When the lockout has been cleared successfully, the Room Heater will default to 'Off'. The user must
select the desired power operation to operate the Room Heater.
Figure 6d – Fault display iVan Control Panel
Fault
Check gas supply (1)
This data is confidential to Brunswick
Munster Simms Engineering Ltd., 2 Enterprise Road, Bangor, Co Down, BT19 7TA, U.K. – Northern Ireland
fax.: +44 (0)2891 466 421
iVan display
Action
Ensure that there is gas in the gas bottle and
that there is no blockage in the gas line. At
temperatures below 5°C, use Propane gas
rather than Butane.
Please refer to chapter 4.1.1.1 for additional
recommended checks.
Heat Air Room Heater