4.5 Replacement of Gas Control PCB – AK1845, AK1846, AK1847
Before you start:
! Close gas supply/ isolate 230V supply.
4
3
5
- firmly detach PCB from solenoid lugs. Grip the
3
board close to the lugs, avoiding the use of
sharp objects such as pliers to prevent the
PCB from becoming damaged.
This data is confidential to Brunswick
Munster Simms Engineering Ltd., 2 Enterprise Road, Bangor, Co Down, BT19 7TA, U.K. – Northern Ireland
fax.: +44 (0)2891 466 421
1
2
Heat Air Room Heater
info@whalepumps.com
1
- before starting work a photo of the existing
connections can be taken to refer to.
2
- remove RJ11 cable (1), DC multiplug (2),
HT return (3), GAS O/H stat (4) and
electrode (5).
- PCB will still have connections
4
to remove on opposite face.
www.whalepumps.com