Table Of Contents; Contents - Whale Heat Air SL5511Ux How-To Manual

Table of Contents

Advertisement

tel.: +44 (0)2891 270 531

Contents

Contents .................................................................................................................................................. 2
1.0 General .............................................................................................................................................. 3
1.1 Application .................................................................................................................................... 3
................................................................................................................................ 3
2.1 Product Description ...................................................................................................................... 5
2.2 Product Operation ........................................................................................................................ 5
3.0 Fault Trees ......................................................................................................................................... 6
4.0 Troubleshooting .............................................................................................................................. 11
4.1 Lock outs/Fault codes ................................................................................................................. 11
4.1.1 Clear lockout procedure Heat and Duo Control Panel ......................................................... 11
4.1.1.1 - 1 Bar: No flame detected ............................................................................................... 11
4.1.1.2 - 2 Bars: Overheat ............................................................................................................. 12
4.1.1.3 - 3 Bars: Low/High supply voltage .................................................................................... 12
4.1.1.4 - 4 Bars: Combustion air fault ........................................................................................... 13
4.1.1.5 - 5 Bars: Room Heater issues ............................................................................................ 13
4.1.1.6 - All Bars: Multiple faults .................................................................................................. 13
4.1.2 Clear lockout procedure iVan Control Panel ........................................................................ 14
4.2 Whale returns procedure ............................................................................................................ 15
4.3 Initial steps required before replacing internal parts ................................................................. 17
4.4 Replacement of Blown Air Fan - AK1834 .................................................................................... 17
4.5 Replacement of Gas Control PCB - AK1845, AK1846, AK1847 ................................................... 18
4.6 Replacement of Electric Control PCB - AK1849 .......................................................................... 19
4.7 Gas Component Replacement .................................................................................................... 20
4.7.1 Replacement of Solenoid Coils - AK1842, AK1843, AK1844.................................................... 20
4.7.2 Replacement of Motor Units ................................................................................................... 21
4.7.4 Replacement of Gas Heat Exchanger - AK1840 ....................................................................... 23
4.8 Gas Overheat (O/H) Thermostat check and replacement - AK1854 ........................................... 23
4.10 Assessment and replacement of Electric Element AK1850 ...................................................... 25
5.0 Spare parts ...................................................................................................................................... 26
6.0 Contact details ................................................................................................................................ 29
This data is confidential to Brunswick
Munster Simms Engineering Ltd., 2 Enterprise Road, Bangor, Co Down, BT19 7TA, U.K. - Northern Ireland
fax.: +44 (0)2891 466 421
Heat Air Room Heater
info@whalepumps.com
www.whalepumps.com
Page
|
2 of 34

Advertisement

Table of Contents
loading

Table of Contents