Compressor / Engine Specifications; Reference Conditions; Limitations - Atlas Copco XRVS 1000 CD8 T4F HOP Instruction Manual

Portable compressors
Table of Contents

Advertisement

Compressor / engine specifications

REFERENCE CONDITIONS

Designation
Absolute inlet pressure
Relative air humidity
Air inlet temperature
Nominal effective working pressure
The inlet conditions are specified at the air inlet grating outside the canopy.

LIMITATIONS

Designation
Minimum effective receiver pressure
Maximum effective receiver pressure, compressor unloaded
Maximum ambient temperature at sea level
Minimum starting temperature
Minimum starting temperature, with coldstart equipment
Altitude capability
Units
bar(e)
1.013
psi
14.7
%
0
°C
20
°F
68
bar(e)
25.16
psi
365
Units
bar(e)
21.02
psi
305
bar(e)
35.02
psi
508
°C
50
°F
122
°C
-23.33
°F
-10
°C
-31.66
°F
-25
ft
See Performance Curve
- 79 -
XRVS 1000 CD8 T4F
365 psi
1.013
14.7
0
20
68
35.02
508
XRVS 1000 CD8 T4F
365 psi
21.02
305
35.02
508
50
122
-23.33
-10
-31.66
-25
See Performance Curve
508 psi
508 psi