The engine will now run at maximum rpm, the display will
show
MAIN VIEW
PREPARING TO LOAD
4.7
41%
1286h
1800RPM
The loading valve will be energized and pressure starts
building up.
Active Buttons
Stop Button
(to cancel Start command)
Load Button
(to cancel Load command)
Measurement View Button
Settings View Button
Alarms View Button
During loading the following display is shown (default
display
MAIN VIEW
LOADED
4.7bar
41%
The controller controls the speed of the engine in order to
meet the requested working pressure, at the most
economical fuel usage.
Stop Button
(to cancel Start command)
Load Button
(to cancel Load command)
Measurement View Button
Settings View Button
Alarms View Button
18.6
1286h
1424RPM
18.6bar
Active Buttons
- 39 -
During operation
The doors must be closed during operation
and may be opened for short periods for
inspection and adjustments only.
Be aware not to touch hot parts when the
door is open.
When the engine is running, the air outlet
valves (ball valves) must always be put in a
fully opened or fully closed position.
Regularly carry out following checks:
1. Ensure that the regulating valve (RV) is correctly
adjusted, i.e. starts decreasing the engine speed when
reaching the preset working pressure in the receiver.
2.
Check the air outlet temperature of the compressor
element.
3.
Check the engine oil pressure, the coolant tempera-
ture and display of control box.
4.
Avoid the engine running out of fuel. Nevertheless, if
this happens, fill the fuel tank and prime the fuel sys-
tem to speed up starting.