Fault Codes - Atlas Copco XRVS 1000 CD8 T4F HOP Instruction Manual

Portable compressors
Table of Contents

Advertisement

FAULT CODES

There are several parameters that are continuously
watched.
Alarmcode
1231
FUEL FILL CHECK
1503
INITIAL OVERHAUL REQUIRED
1522
MINOR OVERHAUL WITHIN ** h
1523
MINOR OVERHAUL WITHIN ** d
1524
MINOR OVERHAUL REQUIRED
1552
MAJOR OVERHAUL WITHIN ** h
1553
MAJOR OVERHAUL WITHIN ** d
1554
LOAD PREVENTION - FIRE RISK
1558
COMP. OIL CHANGE WITHIN ** h
1559
COMP. OIL CHANGE WITHIN ** d
2000
EMERGENCY STOP INPUT
2040
REMOTE EMERGENCY STOP
2070
COOLANT LEVEL LOW WARNING
2080
COOLANT LEVEL LOW SHUTDOWN
Δp AIRFILTERS HIGH
2090
2100
NO PROJECTFILE DOWNLOADED
2752
NAM OILTRONIX BYPASS CIRCUIT
2762
NAM OILTRONIX CLOSED CIRCUIT
2772
NAM AIRXPERT OPENED CIRCUIT
2782
NAM AIRXPERT CLOSED CIRCUIT
3000
FUEL LEVEL LOW WARNING
3010
FUEL LEVEL LOW SHUTDOWN
3020
FUEL LEVEL SENSOR CIRCUIT
3050
VESSEL PRESSURE HIGH WARNING
3060
VESSEL PRESSURE HIGH SHUTDOWN
3070
VESSEL PRESSURE SENSOR CIRCUIT
3120
REGULATING PRESSURE SENSOR CIRCUIT
3170
AIR DISCHARGE PRESSURE SENSOR CIRCUIT
3320
INLET PRESSURE SENSOR CIRCUIT
3450
BATTERY LOW ALARM
3460
BATTERY HIGH ALARM
3660
FIRE RISK - CHECK OILSTOPVALVE
3680
OSV PRESSURE SENSOR CIRCUIT
3720
INTERSTAGE PRESSURE SENSOR CIRCUIT
When one of these parameters exceeds its specified limit
the compressor will react depending the present status of
the control box.
Alarmtext
- 47 -
Failclass
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Inhibit Load
Warning
Warning
Shutdown
Shutdown
Warning
Shutdown
Warning
Warning
Shutdown After Stop
Shutdown After Stop
Shutdown
Shutdown
Warning
Controlled Stop
Warning
Controlled Stop
Shutdown
Shutdown
Shutdown
Warning
Shutdown
Indication
Warning
Shutdown
Controlled Stop
Warning
Trigger
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc
Xc

Advertisement

Table of Contents
loading

Table of Contents