Panel display
Code
(last 4
Large LCD
digits)
260E
Hardware error.
03130031-260E
Turn off printer,
wait, then
turn on again.
260F
Gap error.
Turn off printer.
2618
Hardware error.
03130031-2618
Turn off printer,
wait, then
turn on again.
Small LCD
Power On
Again
Gap Detect Err
Power On
Again
Gap Error
Explanation/Detection sequence
Gap detection failure
Carriage gap calibration has not been
carried out, or gap detection is disabled by
corrupt calibration data.
Gap reference plane error
Request to replace an abnormal reference
plane sheet (only in Service mode).
Vh voltage error
2-24
Chapter 2 Indexes by Case
Remedial Action
(★: Reference fault
isolation procedure
or tool)
①Check to see if
the
multisensor
reference
plate (white
patch for batch
correction) is
not soiled and
perform GAP
CALIB (if
soiled, adjust
the part after
replacing it).
②Replace the
multisensor
and perform
GAP CALIB.
③Replace the
carriage unit
and perform
GAP CALIB.
Check the
multisensor
reference plate
(for soiling and
faulty mounting).
Go to Flow 1 in ★
2010 (P3-12)
Go to ⑩ (all
nozzles on a
single- or
double-head
model not
discharging) in
★T02(P4-5).