Canon iPF9000S Troubleshooting Manual page 164

Ipf8000 series; ipf9000 series; ipf800 series; ipf700 series; ipf650 series; ipf750 series; ipf5000 series; ipf6000 series; ipf500 series; ipf600 series
Hide thumbs Also See for iPF9000S:
Table of Contents

Advertisement

■Periodically replaced/consumable parts counter (iPF5000 example)
PARTS CO UNTER
CO UNTER A : O K
796
PARTS A1 :
CO UNTER B : O K
796
PARTS B1 :
CO UNTER D : O K
796
PARTS D1 :
179143
PARTS D2 :
PARTS D3 :
158057
PARTS D4 :
CO UNTER F : O K
796
PARTS F1 :
CO UNTER H : O K
796
PARTS H1 :
CO UNTER L : O K
796
PARTS L1 :
CO UNTER P : O K
796
PARTS P1 :
CO UNTER Q : O K
796
PARTS Q 1 :
CO UNTER R : O K
796
PARTS R1 :
CO UNTER V : O K
796
PARTS V1 :
■Other display items (iPF8000S example)
Cal i br at i on Hi st or y ( Last 20t i m es)
Dat e
Act i on M edi a
1: 2008/08/18 0
2: 2008/08/06 0
3: 2008/08/04 2
M ul t i Sensor
Uni t Ver : 01
DATA :
02 55 20 07 05 08 16 25 01 00 00 00 00 00 00 00
20 81 dc 01 02 81 a8 01 02 81 7c 01 02 01 03 00
CR REG
C2
15
9
5
2
8
9
10
11
3
1
0
-2
BK
12
9
7
5
8
9
10
11
5
4
2
1
C
-6
-5
-4
-4
-3
-3
-3
-4
-2
-2
-2
-1
0. 0
36. 1
0%
0. 0
48. 3
0%
13028571
1%
97344
6700000
1%
16500000
0%
4733
60000
7%
97344
4000000
2%
2586
50000
5%
111
12500
0%
6
750
0%
1572
27500
5%
1697
27500
6%
0. 0
15. 2
0%
Tem p[ C] /Hum i d[ %]
Gl ossy Phot o
1
-1
-2
-3
-2
12
12
12
11
10
-4
-4
-4
-3
-1
4
3
2
1
1
11
12
11
11
10
-1
-2
-2
-1
0
-4
-3
-2
-2
-1
-4
-4
-4
-4
-4
-1
-1
-1
0
0
0. 0
0. 0
179143
97344
158057
4733
97344
2586
111
6
1572
1697
0. 0
Calibration history
(iPF9100/9000S/8100/8000S/6200/6100/6000S/5100 only)
Up to 20 cycles printed (or as many as there are histories if
less than 20 cycles)
Date/Action/Media/Temp/Humid
25/ 57
(iPF9100/9000S/8100/8000S/6200/6100/6000S/5100 only)
If the multisensor has been replaced, the new unit version
prints in the Media field (00/01).
The contents of the first 32 bytes of EEPROM also print.
Unit Ver/DATA
CR REG adjustment values (iPF8000/8000 Series only)
iPF8000S, iPF9000S: C2/BK/C
iPF8000, iPF9000:
※All values appear as 0 if CR_REG is yet to be executed.
-2
0
2
4
5
9
8
7
6
5
2
0
2
3
4
5
6
9
8
7
7
6
3
0
-1
-1
-2
-2
-3
-4
-4
-3
-3
-3
0
0
5-4
Chapter 5 Miscellaneous Information
B1: Platen duct
Count (dot count mL)
L1: Non-discharging unit
Count (non-ejection count)
Q1: Cassette pickup roller
Count (Cassette pickup count)
R1: Spur lift cam
Count (Total paper feed count)
V1: Mist collection system
Count (dot count mL)
B/M/Y
7
7
5
4
7
7
6
5
-3
-3
-3
-2

Advertisement