Air Filter Elements; Removal; Reassembly; Ventilation - Ingersoll-Rand XHP1070WCAT Operating & Maintenance Manual

Hide thumbs Also See for XHP1070WCAT:
Table of Contents

Advertisement

Operating & Maintenance Manual
Follow the instructions provided by the antifreeze supplier when
adding or draining the antifreeze solution. It is advisable to wear
personal protective equipment to prevent skin and eye contact with
the antifreeze solution.

Air Filter Elements

The air filter element should be replaced regularly (refer to the MAINTENANCE CHART)
or when the restriction indicator shows red, whichever comes first. The aircleaner
precleaner dumps should be cleaned as indicated in the MAINTENANCE CHART (more
frequently in dusty operating conditions).

Removal

Never remove and replace element(s) when the machine is running.
Clean the exterior of the filter housing and remove the filter element by releasing the nut.

Reassembly

Assemble the new element into the filter housing ensuring that the seal seats properly.
Secure element by tightening nut.
Before restarting the machine, check that all clamps are tight.

Ventilation

Always check that the air inlets and outlets are clear of debris etc.

Cooling Fan Drive

Periodically check that the fan mounting bolts in the fan hub have not loosened. If, for any
reason, it becomes necessary to remove the fan or re-tighten the fan mounting bolts, apply
a good grade of commercially available thread locking compound to the bolt threads and
tighten to the torque value shown in the TORQUE SETTING TABLE later in this section.
The fan belt(s) should be checked regularly for wear and correct tensioning.
56
WARNING
!
CAUTION
!
Maintenance
Book: 22742944 (3-17-06) Rev. A