Before Starting

Open manual blowdown valve to ensure the separator has been vented of all pressure. Close
the valve before starting.
Inspect the complete installation including remote fuel lines (if any) and air hose routing and
connections.
Check battery for proper connections and condition.
Combustible gas can cause severe burns, blindness or death. Keep
sparks and open flame away from battery.
Check the compressor fluid level. Maintain the fluid level between bottom and
midway of the sight glass on the separator tank.
Check engine oil level. The proper level is labeled on the engine dipstick. Add oil
when required. Do not overfill.
To jump-start, connect the positive booster/charger cable to the 24VDC positive (+)
terminal of the battery. Then connect the negative booster/charger cable to the
engine block...Not to the negative (-) terminal of the weak battery. After starting,
disconnect the negative (-) cable from engine block; then from the booster battery/
charger. Disconnect positive (+) cable from both batteries.
Do not remove the cap from a HOT engine radiator. The sudden release
of pressure from a heated cooling system can result in a loss of coolant
and possible severe personal injury.
Hot pressurized fluid can cause serious burns. Do not open radiator while
hot.
Check coolant to assure coolant level is at minimum level when the unit is cold.
Check engine coolant level on coolant recovery bottle on inside of rear door. Add coolant as
required.
Insure that radiator cap is installed properly and tightened.
36
WARNING
!
WARNING
!
WARNING
!
Operating Instructions
Book: 22742944 (3-17-06) Rev. A