Page 1
This manual must be available to the personnel who operate and maintain this machine. Doosan purchased Bobcat Company from Ingersoll-Rand Company in 2007. Any reference to Ingersoll-Rand Company or use of trademarks, service marks, logos, or other proprietary identifying marks belonging P.O.
Page 2
QUALITY POLICY We will supply products and services that consistently meet the requirements of our customers and each other. CALIFORNIA Proposition 65 Warning Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm.
This manual contains instructions and technical data to cover all routine operation and scheduled maintenance tasks by operation and maintenance staff. Major overhauls are outside the scope of this manual and should be referred to an authorised Ingersoll-Rand service department.
Page 9
Use of this machine in potentially explosive atmospheres, including situations where flammable gases or vapours may be present. Use of the machine fitted with non Ingersoll-Rand approved components/lubricants/fluids. Use of the machine with safety or control components missing or disabled.
Page 10
**Always use Ingersoll-Rand Replacement parts!** 22560858...
Oil-Free airends are fee-based and may require a maintenance agreement. Formal enrollment is required. Ingersoll-Rand will provide a new part or repaired part, at its election, in place of any part, which is found upon its inspection to be defective in material and workmanship during the period prescribed above.
Warranty Operation & Maintenance Manual General Warranty Information Comments Portable Package 12 Months/ Covers controls, switches, sheet metal, Compressor 2,000 Hours radiator, oil cooler, receiver, pipework, electrical circuit etc. Airend 24 Months/ 60 months/10,000 hours. extended limited 4,000 Hours warranty available on major components. Refer to operator’s manual.
Page 14
Ingersoll-Rand 4,000 Extended warranty of 60 months/10,000 hrs. When using genuine Ingersoll-Rand fluids and parts on major components. Kubota (North 2,000 Extended warranty of 36 months/3,000 hrs. on major America only) components, parts only, available from Kubota.
Machines shipped outside the United States require notification be made to initiate the machine warranty. Fill out the Warranty Registration Form in this section, keep a copy for your records and mail form to: Ingersoll-Rand Company Portable Compressor Division P.O. Box 868 Mocksville, North Carolina 27028 Attn: Warranty Department NOTE: Completion of this form validates the warranty.
Page 16
The warranty and limitation of liability has been reviewed and understood by the owner/user. In the event that this unit is to be used within a nuclear facility, the owner/user shall notify Ingersoll-Rand of such use so that Ingersoll-Rand may arrange for appropriate nuclear liability protection from the owner-licensee of the facility.
Operation & Maintenance Manual Noise Emission Noise Emission Control Maintenance Log COMPRESSOR MODEL_________________________ SERIAL NO. __________________________________ USER UNIT NO. _______________________________ UNIT IDENTIFICATION DEALER OR DISTRIBUTOR FROM WHOM PURCHASED: Engine Make & Model:_________________ Serial No.:__________________________ __________________________________ Purchaser or Owner:__________________ __________________________________ Address: ___________________________ Date Purchased:_____________________ __________________________________ The Noise Control Act of 1972 (86 Stat.
Noise Emission Operation & Maintenance Manual Introduction The unit for which this Maintenance Log is provided conforms to U.S. E.P.A. Regulations for Noise Emissions, applicable to Portable Air Compressors. The purpose of this book is to provide (1) the Maintenance Performance Schedule for all required noise emission controls and (2) space so that the purchaser or owner can record what maintenance was done, by whom, where and when.
Inspect and maintain engine condition and operation as recommended in the manuals supplied by the engine manufacturer. J. Fuels and Lubricants Use only the types and grades of fuels and lubricants recommended in the Ingersoll-Rand Company and Engine Manufacturer’s Operator and Maintenance Manuals. 22560858...
Page 23
Noise Emission Operation & Maintenance Manual Table 1: MAINTENANCE RECORD FOR NOISE EMISSION CONTROL AND EXTENDED WARRANTY ITEM NO. DESCRIPTION OF WORK OR HOURMETER MAINT/ LOCATION WORK DONE COMMENTS READING INSPECT DATE CITY/STATE BY (NAME) 22560858...
Page 24
**Always use Ingersoll-Rand Replacement parts!** 22560858...
Operation & Maintenance Manual Safety Symbols Safety Symbols Look for these signs on machines manufactured in North America, which point out potential hazards to the safety of you and others. Read and understand thoroughly. Heed warnings and follow instructions. If you do not understand, inform your supervisor.
Operation & Maintenance Manual Safety Safety General Information Ensure that the operator reads and understands the decals and consults the manuals before maintenance or operation. Ensure that the Operation and Maintenance manual, and the manual holder, are not removed permanently from the machine. Ensure that maintenance personnel are adequately trained, competent and have read the Maintenance Manuals.
Safety Operation & Maintenance Manual All pressure containing parts, especially flexible hoses and their couplings, must be regularly inspected, be free from defects and be replaced according to the Manual instructions. Avoid bodily contact with compressed air. The safety valve located in the separator tank must be checked periodically for correct operation.
Operation & Maintenance Manual Safety Battery Batteries contain corrosive liquid and produce explosive gas. Do not expose to naked lights. Always wear personal protective clothing when handling. When starting the machine from a slave battery ensure that the correct polarity is observed and that connections are secure. DO NOT ATTEMPT TO SLAVE START A FROZEN BATTERY SINCE THIS MAY CAUSE IT TO EXPLODE.
Maximum towing speed 20mph (35kph) High Speed Running Gear (HSRG) Number of wheels. Tire size. 8-14.5 LT/G Tire pressure. 110 psi (7.6 bar) Maximum towing speed 65 mph (105kph) Further information may be obtained by request through Ingersoll-Rand customer services department. 22560858...
Page 40
**Always use Ingersoll-Rand Replacement parts!** 22560858...
Operation & Maintenance Manual Operating Instructions Operating Instructions Commissioning Upon receipt of the unit, and prior to putting it into service, it is important to adhere strictly to the instructions given below in PRIOR TO STARTING. Ensure that the operator reads and understands the decals and consults the manuals before maintenance or operation.
Page 43
Operating Instructions Operation & Maintenance Manual WARNING If more than one compressor is connected to one common downstream plant, effective check valves and isolation valves must be fitted and controlled by work procedures, so that one machine cannot accidently be pressurised/over pressurised by another.
Operation & Maintenance Manual Operating Instructions Prior to Starting 1. Place the unit in a position that is as level as possible. The design of the unit permits a 15 degree lengthways and sideways limit on out of level operation. When the unit has to be operated out of level, it is important to keep the engine oil level near the high level mark (with the unit level).
Page 45
Operating Instructions Operation & Maintenance Manual CAUTION 8. Do not operate the machine with the canopy/doors in the open position as this may cause overheating and operators to be exposed to high noise levels. 9. Check the emergency stop. Rotate knob as indicated to release. 10.
Operation & Maintenance Manual Operating Instructions Operating Controls and Instruments The operating controls and instruments are arranged on the control panel as shown above. A description of each panel device is as follows: 1. Panel Light: Illuminates the instrument control panel controlled by Switch 14. 2.
Page 47
Operating Instructions Operation & Maintenance Manual 20. Discharge Air Pressure Gage: Indicates pressure in receiver tank, normally from 0 psi(kPa) to the rated pressure of the machine. 21. Engine Tachometer: Indicates engine speed in RPM from 0 when stopped to full speed.
Operation & Maintenance Manual Operating Instructions Wedge Diagnostic Display Codes 1. High Compressor Temp: Fault indicator lamp. Indicates shutdown due to high compressor temperature. 2. Low Engine Oil Pressure: Fault indicator lamp. Indicates shutdown due to low engine oil pressure. 3.
Page 49
Operating Instructions Operation & Maintenance Manual 7. Restricted Air Filter: Alarm indicator lamp. Indicates engine/compressor air inlet filters need service. 8. Restricted IQ Air Filters: Fault indicator lamp. Indicates shutdown due to high pressure in “IQ” air filters (if equipped). 9.
Operation & Maintenance Manual Operating Instructions Cummins Engine Model QSL-9s Displayed Code Definition Engine Control Module - Critical internal failure Engine Speed/Position Sensor Circuit - lost both of two signals from the magnetic pickup sensor Engine Speed/Position Sensor Circuit - lost one of two signals from the magnetic pickup sensor Intake Manifold Pressure Sensor #1 Circuit - shorted high Intake Manifold Pressure Sensor #1 Circuit - shorted low...
Page 53
Operating Instructions Operation & Maintenance Manual Displayed Code Definition Engine Speed High v Critical Engine Coolant Level Low - Critical Vehicle Speed Sensor Circuit - data incorrect Vehicle Speed Sensor Circuit - tampering has been detected Engine Brake Driver #1 Circuit - shorted low Fan Clutch Circuit - shorted low Fuel Temperature Sensor Circuit - shorted high Fuel Temperature Sensor Circuit - shorted low...
Page 54
Operation & Maintenance Manual Operating Instructions Displayed Code Definition Transmission Output Shaft (Tailshaft) Speed High - Warning Sensor Supply Voltage #1 Circuit - shorted low Intake Air Heater (Relay Enable) #1 Circuit - data incorrect Intake Air Heater (Relay Enable) #2 Circuit - data incorrect OEM Sensor Supply Voltage Circuit - shorted high Sensor Supply Voltage #1 Circuit - shorted high Accelerator Pedal Position Sensor Supply Voltage Circuit - shorted high...
Operation & Maintenance Manual Operating Instructions Starting the Machine Ensure emergency stop button is reset. WARNING Under no circumstances should volatile fluids such as ether be used for starting this machine. All normal starting functions are incorporated in the key operated switch. Turn the keyswitch to (position 1);...
Operating Instructions Operation & Maintenance Manual NOTE: In order to allow the machine to start at a reduced load, a valve, which is operated by a service air switch located on the instrument panel, is incorporated in the regulation system. (The valve automatically returns to the start position when the machine is switched off and air pressure relieved from the system).
Operation & Maintenance Manual Operating Instructions CAUTION Never allow the machine to stand idle with pressure in the system. Emergency Stopping In the event that the unit has to be stopped in an emergency, PRESS THE EMERGENCY STOP SWITCH ON THE FRONT OF THE MACHINE. If the unit is not fitted with an emergency stop switch, rotate the start switch to the (0) off position.
Operating Instructions Operation & Maintenance Manual Decommissioning When the machine is to be permanently decommissioned or dismantled, it is important to ensure that all hazard risks are either eliminated or notified to the recipient of the machine. In particular:- • Do not destroy batteries or components containing asbestos without containing the materials safely.
Page 60
**Always use Ingersoll-Rand Replacement parts!** 22560858...
Operation & Maintenance Manual Maintenance Maintenance Maintenance Interval Chart Maintenance Interval Chart Initial Daily Weekly Monthly Monthly. Monthly. Monthly. miles 500 hrs. 1000 hrs 2000 hrs /850 km Compressor Oil Level Engine Oil Level *Radiator Coolant Level Gauges/Lamps *Air Cleaner Service Indicators Fuel Tank (Fill at end of day) *Fuel/Water Separator Drain Oil Leaks...
Page 63
Maintenance Operation & Maintenance Manual *Disregard if not appropriate for this particular machine. (1) or 3000 miles/5000km whichever is the sooner (2) or as defined by local or national legislation C = Check (adjust, clean or replace as necessary) CBT = check before towing. CR = Check and report D = Drain G = Grease...
Page 65
Maintenance Operation & Maintenance Manual *Disregard if not appropriate for this particular machine. (1) or 3000 miles/5000km whichever is the sooner (2) or as defined by local or national legislation C = Check (adjust, clean or replace as necessary) CBT = check before towing. CR = Check and report D = Drain G = Grease...
Page 66
Operation & Maintenance Manual Maintenance Initial Daily Weekly Monthly Monthly. Monthly. Monthly. miles 500 hrs. 1000 hrs 2000 hrs /850 km Separator tank (2) exterior Lubricator (Fill) * 2 Yrs 4 Yrs 6 Yrs Safety valve Hoses Separator tank (2) interior *Disregard if not appropriate for this particular machine.
Maintenance Operation & Maintenance Manual Routine Maintenance This section refers to the various components which require periodic maintenance and replacement. The SERVICE MAINTENANCE INTERVAL CHART indicates the various components’ descriptions and the intervals when maintenance has to take place. Oil capacities, etc., can be found in the GENERAL INFORMATION section of this manual.
Page 68
Operation & Maintenance Manual Maintenance Prior to opening or removing panels or covers to work inside a machine, ensure that:- • anyone entering the machine is aware of the reduced level of protection and the additional hazards, including hot surfaces and intermittently moving parts. •...
Maintenance Operation & Maintenance Manual Protective Shutdown System Refer to the Wedge diagnostic display codes table for a listing of shutdown conditions. Low engine fuel level switch At three month intervals, test the low engine fuel level switch circuit as follows: •...
Operation & Maintenance Manual Maintenance Compressor Oil Filter Refer to the MAINTENANCE INTERVAL CHART in this section for the recommended servicing intervals. Removal WARNING Do not remove the filter(s) without first making sure that the machine is stopped and the system has been completely relieved of all air pressure. (Refer to STOPPING THE UNIT in the OPERATING INSTRUCTIONS section of this manual).
Maintenance Operation & Maintenance Manual Compressor Oil Separator Element Refer to the SERVICE MAINTENANCE INTERVAL CHART in this section for service intervals. Removal WARNING Do not remove the filter(s) without first making sure that the machine is stopped and the system has been completely relieved of all air pressure. (Refer to STOPPING THE UNIT in the OPERATING INSTRUCTIONS section of this manual).
Operation & Maintenance Manual Maintenance CAUTION Start the machine (refer to PRIOR TO STARTING and STARTING THE UNIT in the OPERATING INSTRUCTIONS section of this manual) and check for leakage before the machine is put back into service. Compressor Oil Cooler & Engine Radiator Air Charge Cooler When grease, oil and dirt accumulate on the exterior surfaces of the oil cooler and radiator, the efficiency is impaired.
Maintenance Operation & Maintenance Manual Air Filter Element The air filter should be inspected regularly (refer to the SERVICE MAINTENANCE INTERVAL CHART) and the element replaced when the restriction indicator lamp illuminates. The dust collector box(es)should be cleaned daily (more frequently in dusty operating conditions) and not allowed to become more than half full.
Operation & Maintenance Manual Maintenance Ventilation Always check that the air inlets and outlets are clear of debris etc. CAUTION NEVER clean by blowing air inwards. Cooling Fan Drive Periodically check that the fan mounting bolt in the fan hub has not loosened. If, for any reason, it becomes necessary to remove the fan or re-tighten the fan mounting bolt, apply a good grade of commercially available thread locking compound to the bolt threads and tighten to the torque value shown in the TORQUE SETTING TABLE later in this section.
Maintenance Operation & Maintenance Manual Electrical System WARNING Always disconnect battery cables before performing maintenance or service. Inspect the safety shutdown system switches and the instrument panel relay contacts for evidence of arcing and pitting. Clean where necessary. Check the mechanical action of the components. Check the security of electrical terminals on the switches and relays i.e.
Operation & Maintenance Manual Maintenance Running Gear/Wheels Check the wheel nut torque 20 miles (30 kilometres) after refitting the wheels. Refer to the TORQUE SETTING TABLE later in this section. The bolts securing the running gear to the chassis should be checked periodically for tightness (refer to the SERVICE/MAINTENANCE CHART for frequency) and re-tightened where necessary.
CAUTION Some oil mixtures are incompatible and result in the formation of varnishes, shellacs or lacquers which may be insoluble. NOTE: Always specify INGERSOLL-RAND Pro-Tec oil for use at all ambient temperatures above -23°C. For extended warranty use only IR fluids. Refer to portable compressor fluids chart.
Operation & Maintenance Manual Maintenance Running Gear Wheel Bearings Wheel bearings should be packed with grease every 6 months. The type of grease used should conform to specification MIL-G-10924. XP1000, XP950, HP915, MHP825, VHP750 Adjusting screw Orifice Separator tank Regulation pressure Manual blowdown Mini compressor transducer...
Maintenance Operation & Maintenance Manual Speed & Pressure Regulation Adjustment Normally, regulation requires no adjusting, but if correct adjustment is lost, proceed as follows: Refer to the diagram above. A Adjusting screw Start the machine (Refer to STARTING INSTRUCTIONS in the OPERATING INSTRUCTIONS section of this manual).
Page 80
Operation & Maintenance Manual Maintenance XHP700 Regulation pressure Air cylinder Pressure transducer transducer Minimum pressure Butterfly valve Start/Run solenoid valve Mini compressor Pressure regulator Separator tank Unloader Solenoid Panel pressure guage Auto blowdown valve Manual blowdown Relief valve HR2 Airend valve Orifice Temperature sensor...
Maintenance Operation & Maintenance Manual Speed & Pressure Regulation Adjustment Normally, regulation requires no adjusting, but if correct adjustment is lost, proceed as follows: Refer to the diagram above. With the unit stopped, disconnect ballast spring ‘A’ from the butterfly lever. Loosen the two screws securing bracket ‘C’...
Operation & Maintenance Manual Maintenance Portable Compressor Fluid Chart Refer to these charts for correct compressor fluid required. Note that the selection of fluid is dependent on the design operating pressure of the machine and the ambient temperature expected to be encountered before the next oil change. NOTE: Fluids listed as “preferred”...
Page 85
Maintenance Operation & Maintenance Manual Recommended Ingersoll-Rand Fluids - Use of these fluids with original IR filters can extend airend warranty. Refer to operator’s manual warranty section for details or contact your IR representative. Ingersoll-Rand 1 gal. 5 gal. 5 gal.
Page 86
**Always use Ingersoll-Rand Replacement parts!** 22560858...
Operation & Maintenance Manual Fault Finding Fault Finding FAULT CAUSE REMEDY No reaction from Emergency stop Reset emergency stop button. instrument panel actuated. when key turned to Batteries not connected. Connect batteries. (I) position. Fuse at starter motor Replace fuse. ‘blown’.
Page 95
Fault Finding Operation & Maintenance Manual FAULT CAUSE REMEDY Engine starts but Electrical fault. Test the electrical circuits. will not run or Low engine oil pressure. Check the oil level and oil filter(s). engine shuts down prematurely. Safety shut-down Check the safety shut-down switches. system in operation.
Page 96
Dirty or blocked oil Clean the oil cooler fins. cooler. Incorrect grade of oil. Use Ingersoll-Rand recommended oil. Defective by-pass valve. Check the operation of the element and replace if necessary. Recirculation of cooling Move the machine to avoid recirculation.
Page 97
Fault Finding Operation & Maintenance Manual FAULT CAUSE REMEDY Safety valve Operating pressure too Check the setting and operation of the operates. high. regulator valve piping. Incorrect setting of the Adjust the regulator. regulator. Faulty regulator. Replace the regulator. Inlet valve set Refer to SPEED AND PRESSURE incorrectly.
Page 98
**Always use Ingersoll-Rand Replacement parts!** 22560858...
Options Operation & Maintenance Manual IQ System The IQ System is a complete, self-contained system which provides cooler, cleaner air than from a standard portable compressor. The system utilizes an integral aftercooler, high-efficiency filtration, and a patented condensate disposal system to provide the cool, clean air.
TCU to further close the louvers if the compressed air temperature falls to approximately 36°F (2°C) or lower. There are no user selectable or serviceable components in the TCU. Contact Ingersoll-Rand Service if any abnormal operation of the freeze protection control system occurs.
Options Operation & Maintenance Manual • Remove and replace the filter element, being careful not to damage outer wrap. Verify the part number of new element vs. old element, as the two IQ filters are of different media. Safety CAUTION The compressor regulation system is adjusted to maintain regulated pressure at the separator tank.
Page 104
**Always use Ingersoll-Rand Replacement parts!** 22560858...
Need help?
Do you have a question about the XHP700WCU and is the answer not in the manual?
Questions and answers