Operating & Maintenance Manual
warning signs indicating that Maintenance Work is in Progress are posted in a
position that can be clearly seen.
Upon completion of maintenance tasks and prior to returning the machine into
service, ensure that:-
the machine is suitably tested.
all guards and safety protection devices are refitted.
all panels are replaced, canopy and doors closed.
hazardous materials are effectively contained and disposed of.

Protective Shutdown System

Refer to the diagnostic display codes table for a listing of shutdown conditions.

Low engine fuel level switch.

Test the low engine fuel level switch circuit as follows:
Start the machine.
NOTE: Do not press the load button.
Disconnect the switch, the machine should shutdown.
Re-connect the switch.
Test the low engine fuel level switch by removing and operating the float manually.
Never remove or replace switches when the machine is running.

Scavenge Line

The scavenge line runs from the combined orifice/drop tube in the separator tank, to the
orifice fitting located in the airend.
Check that the scavenge line and tube are clear of any obstruction each time the
compressor lubricant is changed as any blockage will result in oil carryover into the
discharge air.