Maintenance
Fuel System
The fuel tank should be filled daily or every eight hours. To minimise condensation in the
fuel tank(s), it is advisable to top up after the machine is shut down or at the end of each
working day. Drain any sediment or condensate that may have accumulated in the tank(s).
Refer to MAINTENANCE CHART.
Fuel Filter Water Separator
The fuel filter water separator contains a filter element which should be replaced at regular
intervals (see the SERVICE/MAINTENANCE CHART).
Charge Air Cooler Pipework
Inspect all hoses and clamps on the charge cooler pipe work.
Engine damage will occur if the charge cooling system leaks.
Hoses
All components of the engine cooling air intake system should be checked periodically to
keep the engine at peak efficiency.
At the recommended intervals, (see the MAINTENANCE CHART), inspect all of the intake
lines to the air filter, and all flexible hoses used for air lines, oil lines and fuel lines.
Periodically inspect all pipework for cracks, leaks, etc. and replace immediately if
damaged.
Electrical System
Disconnect the battery cables before performing any maintenance or
service.
Check the security of electrical terminals on the switches and relays i.e. nuts or screws
loose, which may cause local hot spot oxidation.
Inspect the components and wiring for signs of overheating i.e. discolouration, charring of
cables, deformation of parts, acrid smells and blistered paint.
Battery
Keep the battery terminals and cable clamps clean and lightly coated with petroleum jelly
to prevent corrosion.