Operating The Generator; Starting The Generator; Stopping The Generator - Sea Ray 58 Sedan Bridge Owner's Manual

Table of Contents

Advertisement

S
ECTION
Q
R
UICK
EFERENCE
G. O
PERATING THE
S
G
TARTING THE
ENERATOR
1. Generator Seacock ...................................................... Open
2. Bilge Blowers ............................................................... Run for at least 4 minutes and any time the generator is running
3. Depress PREHEAT/ON ............................................... Preheat time should not exceed 30 seconds
4. Depress START/RUN Switch ...................................... Depress until generator starts
5. When the Generator Starts .......................................... Release the START switch only continue holding PREHEAT/
6. Load The Generator .................................................... Turn ON the generator main breaker on the Main
S
G
TOPPING THE
ENERATOR
1. Breakers ...................................................................... Turn AC breakers OFF. Turn OFF the generator main breaker
2. Generator ..................................................................... Let it run a few minutes to cool down
3. STOP Switch ............................................................... Depress to stop the generator set
!
WARNING
Do not run the generator or engines in an
enclosed area, such as a closed boat house, as
there is the possibility of buildup and inhaling of
carbon monoxide.
58 Sedan Bridge (585 Sedan Bridge)
8 • R
EQUIRED
M
AINTENANCE
C
(
HECKLIST
CONT
G
ENERATOR
https://www.boat-manuals.com/
I
, S
NSPECTION
'
)
D
ON for a few seconds)
Distribution Panel. Turn AC breakers ON
on the Main Distribution Panel
ERVICE AND
8.13

Advertisement

Table of Contents
loading

This manual is also suitable for:

585 sedan bridge