NOTE: Some functions only read on one line. See
page 2.18 (DCM functions) for all DCM display
readouts.
Backlighting of the LCD is achieved by turning ON
the navigation lights switch. Intensity is controlled
by the electronic dimmer control. Both are located
on the control station switch panel.
A
A
UDIBLE
LARM
An audible alarm will sound to alert the operator to
look at the DCM and determine the high level fault.
Only high level faults such as critical engine
functions, generator, emergency pumps and bilge
heat detector will have an audible alarm. The forward
and aft bilge pumps do not have an audible alarm,
instead the DCM will display those functions.
A
R
/A
UDIBLE
ESET
LARM
The Audible Reset/Alarm Select push button switch
on the DCM is a dual purpose switch. It enables
the operator to reset an audible alarm or to manually
scroll the display during multiple alarms. The Audible
Reset is used to temporarily quiet an alarm that is
displayed on the LCD. If that function is not
corrected within 30 seconds, the audible alarm will
sound again. Pushing the switch again will
permanently quiet (turn off) the audible alarm for
that function. The LCD will still display that fault until
it is corrected.
The Alarm Select is active only during multiple
alarms. For example, if the engine oil pressure,
forward emergency pump and transmission
temperature had faults at the same time, the
systems monitor would sound an audible alarm and
would display the alarm with the highest priority.
!
CAUTION
Never ignore an alarm.
Each push of the switch will show the new alarm
and then the LCD will automatically scroll through
the multiple alarm functions approximately every
three (3) seconds. By pushing on the switch, the
2.18
2 • G
ENERAL
S
ELECT
https://www.boat-manuals.com/
B
A
OAT
RRANGEMENT
operator will be able to manually scroll the LCD for
faulting functions. To monitor critical engine
functions and generator oil pressure:
1. The 24 volt main battery solenoid switches
must be energized either at the main DC
breaker panel on the aft port engine room
component board or the DC distribution
panel in the port aft salon.
2. At the DC distribution panel, turn the port
and starboard master ignition key switches
to the ON position.
3. At the control station, locate the port and
starboard START/RUN switches. Without
starting the engines, push the START/RUN
switches to the RUN position. The Display
Control Monitor (DCM) will display:
SEA RAY BOATS ALL SYSTEMS NORMAL
NOTE: The generator and engines will have an
alarm as soon as ignition is turned on.
4. Start the engines per the engine start
instructions in Section 3, page 3.4.
5. Start the generator per the generator start
instructions in Section 3, page 3.8.
With the main engines and generator engine running,
the yacht's Systems Monitor is fully activated.
When the engine and generator engine ignition is
turned OFF, approximately five (5) minutes display
will be blank. Engine and generator functions are
disabled because they are unnecessary, however,
the bilge heat detector and all pumps are still being
monitored.
The following DCM Function Table will name each
function, describe the function and show how it is
displayed on the DCM.
If your Systems Monitor does not operate or display
functions correctly per the instructions provided,
recycle the circuit breaker by pushing the circuit
breaker to the OFF position and then pushing it to
the ON position. Use a small tool that will fit through
the hole to push the breaker to the OFF position.