Sea Ray 58 Sedan Bridge Owner's Manual page 120

Table of Contents

Advertisement

S
generally require replacement about once a year.
(In salt water areas, replace every six (6) months).
The need to replace anodes more frequently may
indicate a stray current problem within the boat or
at the slip or mooring. If zinc anodes do not need
replacing after one year, they may not be providing
proper protection. Loose anodes or low-grade zinc
may be the problem.
!
CAUTION
Replace zinc sacrificial anodes if they are corroded
50% or more.
DO NOT PAINT BETWEEN THE ZINC AND THE
METAL IT CONTACTS, AND DO NOT PAINT
OVER THE ZINC.
When an AC shore power system is connected to
the boat, the underwater metal fittings will, in effect,
be connected through the water to grounded metals
ashore. The zincs will be consumed at a faster rate
unless the marina maintains a protective system to
prevent this. In this case, hanging a zinc in the water
bonded to the metal outlet box on the dock will
reduce zinc loss on the boat. DO NOT connect
this zinc to the boat's ground system.
6.22
6 • E
ECTION
https://www.boat-manuals.com/
S
LECTRICAL
It is extremely important that all electrically operated
DC equipment and accessories be wired so that
the ground polarity of each device is the same as
that of the battery. Sea Ray
ground system, which is the recommended practice
throughout the marine industry. All metal items (fuel
tanks, underwater gear, etc.) in the boat are
connected to the zinc anode by the green bonding
wire.
19. AC & DC E
S
CHEMATICS
H
ARNESSES
This owner's manual contains electrical
schematics and wiring harness illustrations for
your boat (See pages 6.23 thru 6.78). These
electrical schematics were generated by electrical
CAD designers at the engineering division for
technical reference and service technicians. Sea
®
Ray
does not recommend that you attempt to
work on the boat's electrical system yourself.
Instead we recommend that you take your boat
to your authorized Sea Ray
Sea Ray
®
reserves the right to change or update
the electrical system on any model at any time
without notice to the consumer and is NOT
obligated to make any updates to units built prior
to changes
58 Sedan Bridge (585 Sedan Bridge)
YSTEM
®
boats have a negative
LECTRICAL
& W
IRING
®
dealer for service.