Air Conditioning & Heating - Sea Ray 58 Sedan Bridge Owner's Manual

Table of Contents

Advertisement

S
ECTION
3. A
C
IR
ONDITIONING
The self-contained air conditioning system contains
the compressor, condenser, evaporator, refrigerant,
tubing, electrical box, blower, condensate drip pan
and other components on a single chassis. Cabin
air is pulled into the unit through a return-air grill, and
discharge air is carried through flexible or built-in
ducts to a grill, which is normally located on a
bulkhead high in the compartment. In a self-contained
unit, the refrigerant loop is pre-charged and sealed
at the factory, and no additional charging is needed
at installation.
The 58DB air conditioning/heating system consists
of five (5) standard self contained air conditioning/
heating units, two (2) raw water pumps with
seacocks and strainers and a relay unit so the water
pumps will be activated by demand when any AC
unit comes on. See Cruisair Operators Owners
Manual for specific operating troubleshooting
information.
Care should be taken so as not to stow items around
the air handlers that may block the return air grill.
The air filters for each unit should be removed and
cleaned periodically to assure fresh, clean air
circulation and to reduce stress on the unit.
The forward stateroom unit is located under the
bunk and can be accessed through a hatch under
the mattress. The controls for the unit are located on
the port hanging locker. The removable air filter is
located on the face of the unit. This unit supplies
conditioned air to the forward stateroom, forward
head and shower as well as the starboard stateroom.
The master stateroom unit is located under the
port salon sofa and can be accessed by removing
the sofa cushion. The removable air filter is located
on the face of the unit. The return air plenum is built
into the port aft hanging locker in the master
stateroom. The unit supplies conditioned air not only
to the master stateroom but to the master stateroom
head as well. The controls for the unit are located on
the side of the starboard hanging locker.
7.2
7 • A
CCESSORIES
& H
EATING
https://www.boat-manuals.com/
& O
PTIONS
A
C
L
IR
ONDITIONER
OCATIONS
(F
. 7.2.1)
IG
FORWARD STATEROOM A/C
UNIT (12,000 BTU)
(BELOW BUNK)
GALLEY A/C
UNIT (16,000 BTU)
(BEHIND SOFA)
MASTER STATEROOM A/C
UNIT (12,000 BTU)
(UNDER SOFA)
SALON A/C
UNIT (16,000 BTU)
(BEHIND SOFA)
BRIDGE A/C
UNIT (24,000 BTU)
(OPTIONAL)
(BELOW CONTROL STATION)
58 Sedan Bridge (585 Sedan Bridge)