Terminal board connections
CMN common for all inputs and outputs.
7
8
ELS electric lock output 12 Vdc - 15 W.
9-10 LC-CH2 Potential free contact for the activation of the courtesy light (separate
power supply Vmax=30 Vac/dc: Imax=1A) or the second radio channel. Selec-
tion is carried out in the "options" menu.
11
CMN common for all inputs and outputs.
LP 24 Vdc 25 W output for warning lights intermittent activation (50%),
12
12,5 W continuous activation.
13
LS 24 Vdc 3 W output for an indicator light.
14
CMN common for all inputs and outputs.
15
24 Vdc controlled output, powering external loads
16
CMN common for all inputs and outputs.
24 Vdc output, powering external loads
17
TA (NO contact) opening button input.
18
19
TC (NO contact) closing button input.
20
TAL (NO contact) limited opening button input.
21
TD (NO contact) dynamic button input.
22
CMN common for all inputs and outputs.
TB (
N.C./8.2 kΩ
23
contact) stop button input (The opening of this contact inter-
rupts the cycle until a new movement command is given).
N.C./8.2 kΩ
24
CP (
contact) safety edge input. Opening this contact will provoke a
travel direction inversion during the closing stage and during the opening stage.
N.C./8.2 kΩ
25
FS (
contact) The opening of this contact will block all movement,
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
until the obstruction has been removed and the pause time has elapsed, due
to the safety device cutting in, the door will then continue moving in the closing
direction (only with automatic reclosing enabled).
N.C./8.2 kΩ
26
FI (
contact) safety and control devices in input (photocells invert the
travel direction when an obstruction is detected). Opening this contact will provoke
a travel direction inversion during closure due to the cutting in of the safety device.
27
Outer conductor for radio receiver antenna.
28
Inner conductor for radio receiver antenna (if an external antenna is fitted use
a coaxial type cable RG58 with an impedance of 50Ω).
29
CMN common for the emergency buttons.
31
EMRG1 (NO) emergency manoeuvre input 1.
30
EMRG2 (NO) emergency manoeuvre input 2.
(1)
Note
The total of the 2 external device outputs must not exceed 10 W.
ALL UNUSED NC CONTACTS MUST BE JUMPED and consequently the security
device test (FI , FS ) must also be deactivated. If you want to activate the FI, FS test
both the transmission and receiver parts of the security devices must be connected to
the binding post marked "CTRL 24 Vdc".
TRANSFORMER
L2
J5
F3 10 A
F4 10 A
L1
Collegamento motori/encoder a 4 fili
Connecting motor/4-wire encoder
Branchement moteur/encodeur à 4 fils
Anschluss der Motor/Encoder mit 4 Drähten
Conexionado motores/encoder de 4 conductores
COLORE
COLOUR CODE
CABLAGGI
CODE
Bl
Blu
Blue
Gr
Verde
Green
Gy
Grigio
Grey
Yw
Giallo
Yellow
KABELFARBEN
COLORACIÓN
CABLEADOS
Bl
Blau
Azul
Gr
Grün
Verde
Gy
Grau
Gris
Yw
Gelb
Amarillo
ENCODER 1
M1
Bl
Gr
Gy
Yw
1
2
3
4
5
6
1
B1
Signal buzzer "via radio" mode
(4)
F1
4A
blade fuse
(24V circuit protection)
(4)
F2
4A
blade fuse
(24V circuit protection during battery operation)
(4)
F3
10A blade fuse
(motor power protection)
(4)
F4
10A blade fuse
(motor protection during battery operation)
J1
Display orientation selection (not in use)
J2
Serial connection CSER (not connected)
J3
Battery connection
J4
Battery charger slot
(1)
.
(1)
.
J3
BATTERY
CHARGER
COLORATION
DES CÂBLAGES
Bleu
Vert
Gris
Jaune
LC/CH2
ENCODER 2
M2
Bl
Gr
Gy
Yw
2
3
4
5
6
7
8
9
If the test is active there will be a 1 second delay
between the command transmission and move-
ment of the gate/s.
• Switch on the power and make sure that the
indicator LEDs are in the following condition.
- L1 Power on
- L2 Wrong battery connection OFF
Indications on the display
- S1 Indicator for the blocking button
- S2 Indicator for the inverting photoelectric cells
- S3 Indicator for the stop photoelectric cells
- S4 Indicator for the safety edge
- S5 Indicator for the opening button
- S6 Indicator for the closing button
- S7 Indicator for the sequential command
- S8 Indicator for the limited opening button
Note
: If this LED is "ON" invert the battery power cables immediately.
(2)
Note
: If the security device has not been activated the indications on
(3)
the display are at rest. Make sure that when the security device is
activated the status is inverted (black characters on a white back-
ground).
If the green power on LED "L1" doesn't light up check the condition of the
fuses and the power cable connection at the transformer primary.
If one or more of the safety indications "S1, S2, S3, S4" flash check the
contacts of the relative security devices and check that the unused safety
device contacts have been bridged.
The indications "S5, S6, S7, S8" change status on the display when the
relative command is activated, eg. pressing the button "TA" will change
the status from 'at rest' to 'active'
CS1422A DC0556
J4
B1
R1
10
11
12
13
14
15
16
17
18
J5
Transformer secondary connection
J6
Emergency enable jumper
LCD1 LCD Display
M1
Transmitter code memory module
P1
Menu navigation button (
P2
Programming and confirm button (PROG./OK)
P3
Menu navigation button (
R1
Radio frequency module, 433 MHz (868 MHz on request)
(4)
Note
: These are automotive type blade fuses (max. voltage 58 V)
19
TB FI
S1
FS CP
S3
00.000.007
CC2X24
ON
(2)
at rest activated
TB
(3)
(3)
FI
(3)
FS
(3)
CP
TA
TC
TD
TAL
(white characters on a black background).
J1
M1
P2
P1
PROG/OK
J6
21
24
25
26
27
19
20
22
23
)
)
S2
S5
S7
TA TD
TC TAL
S8
S4
S6
V1.00
TB
FI
FS
CP
TA
TC
TD
TAL
J2
P3
28
29 30 31

Advertisement

Table of Contents
loading

This manual is also suitable for:

200/bl3924csb200/bl3924sb200/bl3924crb200/bl3924rb

Table of Contents